      The i-gel Supraglottic Airway as a Conduit for Fibreoptic Tracheal Intubation – A Randomized Comparison with the Single-use Intubating Laryngeal Mask Airway and CTrach Laryngeal Mask in Patients with Predicted Difficult Laryngoscopy

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Fibreoptic intubation through a supraglottic airway is an alternative plan for airway management in difficult or failed laryngoscopy. The aim of this study was to compare three supraglottic airways as conduits in patients with at least one predictor for difficult laryngoscopy. The i-gel was compared with the single-use intubating laryngeal mask airway (sILMA) and CTrach laryngeal mask in 120 adult patients scheduled for elective surgeries under general anaesthesia using a prospective, randomized and single-blinded design. Primary outcome was success rate of tracheal intubation through the device, while secondary outcomes were times required for device insertion and tracheal tube placement, fibreoptic scores and the incidence of perioperative complications and postoperative complaints. The success rates showed no statistical difference between devices (i-gel 100%, CTrach 97.5%, ILMA 95%). Insertion time was shortest for the i-gel (12.4 s) compared with ILMA (19.3 s) and CTrach (24.4 s). Intubation time was shorter in the i-gel group (29.4 s) in comparison with the CTrach (39.8 s, p<0.05) and sILMA (51.9 s, p<0.001) groups. Best fibreoptic scores were observed also in the i-gel group. In total, 24 patients (20%) presented with difficult laryngoscopy. The i-gel showed significantly shorter times for insertion and fibreoptic intubation than the other two devices in this group. No difference was observed in the incidence of postoperative complaints. The i-gel is a suitable alternative to the sILMA and CTrach for fibrescope-guided tracheal intubation. Shorter insertion and intubation times with the i-gel may provide advantage in case of difficult oxygenation.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: not found
          • Article: not found

          Difficult tracheal intubation in obstetrics

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Assessment of airway visualization: validation of the percentage of glottic opening (POGO) scale.

            Research defining optimal methods of intubation has been limited by the lack of a validated outcome measure to assess airway visualization. The objective of this study was to develop a reliable scale for the assessment of airway visualization during endotracheal intubation. This prospective study was performed to assess the intra- and interphysician reliabilities of emergency physicians (EPs) for estimating the percentage of glottic opening (POGO) that is visualized during direct laryngoscopy. Using video images of laryngeal views obtained from a commercially available videotape, still slide images were prepared representing glottic openings ranging from 0% to 100%. Five EPs, blinded to study objective, reviewed 25 pairs of airway slides (50 slides total). For each slide, the physicians recorded the POGO and their scores using a modified Cormack-Lehane (MCL) scale, where grade I is a view of the full glottic opening, MCL grade II is a partial view of the glottic opening, and MCL grade III is a view of the epiglottis only. Inter- and intraphysician reliabilities were assessed using the kappa statistic (K) for MCL grade and intraclass correlation coefficient for the POGO scores. For the POGO score, the degree of intrarater reliability was very good, with an intraphysician correlation of 0.85 and an interphysician correlation of 0.74. For the MCL score, the intraphysician concordance had a K of 0.71, and interphysician concordance was also good, with a kappa of 0.59. Both the modified version of the Cormack-Lehane grading classification and the POGO score have good interphysician and intraphysician reliabilities. Because the POGO score can distinguish patients with large and small degrees of partial glottic visibility, it might provide a better outcome for assessing the difference between various intubation techniques.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Use of the intubating LMA-Fastrach in 254 patients with difficult-to-manage airways.

              The laryngeal mask airway (LMA; LMA North America, Inc., San Diego, CA) has a well-established role in the emergency and elective treatment of patients with difficult-to-manage airways (DA). In this study, the authors report their clinical experience with the intubating LMA (LMA-Fastrach; LMA North America, Inc., San Diego, CA) in 254 patients with different types of DA. The authors reviewed the anesthetic and medical records of patients with DA in whom the LMA-Fastrach was used electively or emergently at four institutions from October 1997 through October 2000. In each case, the number of insertion and intubation attempts was recorded. Success rates for blind and fiber optically guided intubation through the LMA-Fastrach were calculated, up to a maximum of five attempts per patient. The LMA-Fastrach was used in 257 procedures performed in 254 patients with DA, including patients with Cormack-Lehane grade 4 views; patients with immobilized cervical spines; patients with airways distorted by tumors, surgery, or radiation therapy; and patients wearing stereotactic frames. Insertion of the LMA-Fastrach was accomplished in three attempts or fewer in all patients. The overall success rates for blind and fiber optically guided intubations through the LMA-Fastrach were 96.5% and 100.0%, respectively. The LMA-Fastrach was used successfully in a high percentage of patients who presented with a variety of DA. The clinical experience presented herein indicates that this device may be particularly useful in the emergency and elective treatment of patients in whom intubation with a rigid laryngoscope has failed and in the treatment of patients with immobilized cervical spines.
                Bookmark

                Author and article information

                Journal
                PMRRAD
                Prague Medical Report
                Prague Med. Rep.
                Charles University in Prague, Karolinum Press
                1214-6994
                2336-2936
                2016
                2016
                December 8 2016
                : 117
                : 4
                : 164-175
                Article
                10.14712/23362936.2016.17
                4e54b191-9976-4a8c-a020-b1ac7c0db369
                © 2016
                History

                Comments

                Comment on this article