      Efficiency of biological versus physical optimization for single‐arc VMAT for prostate and head and neck cases

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The aim of this work was to compare different approaches to VMAT optimization (biological vs. physical DVH‐based) in two commercial treatment planning systems (TPS) for head and neck and prostate cases, using Pareto fronts. VMAT vs. IMRT Pareto front comparison was additionally performed in order to benchmark the optimizer efficiency and VMAT plan quality for each TPS. Three prostate and three head and neck cancer patients were selected for nine‐beam IMRT and single‐arc VMAT planning in Monaco 3.00 and Oncentra MasterPlan (OMP) 3.3 planning systems. Pareto fronts for prostate cases were constructed based on PTV coverage by 95% isodose and volume of rectum receiving 60 Gy or more. For head and neck cases, PTV coverage by the same isodose and mean dose to parotid gland were used for the construction of Pareto fronts. DVH analysis was performed together with evaluation of planning and delivery efficiency for all the plans. In the intersystem comparison for prostate plans, Monaco generated very similar IMRT and VMAT solutions. Quality of Monaco VMAT plans was superior compared to Oncentra in terms of conformity, homogeneity, and lower median dose to bladder due to biological formalism of optimization cost functions. For the head and neck cases, IMRT and VMAT plans were similar in both systems, except the case where a very strong modulation was required. In this situation single‐arc VMAT plan generated with OMP was inferior compared to IMRT. VMAT OMP solutions were similar to Monaco or slightly better for two less‐modulated head and neck cases. However, this advantage was achieved on the cost of lower conformity and homogeneity of the Oncentra VMAT plans. IMRT and VMAT solutions generated by Monaco were very similar for both prostate and head and neck cases. Oncentra system shows a bigger difference, and use of the dual‐arc VMAT would be recommended to achieve the same plan quality as nine‐field IMRT. Biological optimization seems beneficial in terms of plan conformity and homogeneity and allowed achieving lower OAR doses for prostate cases. In complex anatomical situations represented by head and neck cases, sequencing algorithm in Monaco imposed limitations on VMAT plan quality in the intersystem comparison.

          PACS numbers: 87.55.de, 87.55.dk, 87.53.Jw

          Related collections

          Most cited references25

          • Record: found
          • Abstract: found
          • Article: not found

          A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note.

          I Paddick (2000)
          A conformity index is a measure of how well the volume of a radiosurgical dose distribution conforms to the size and shape of a target volume. Because the success of radiosurgery is related to the extremely conformal irradiation of the target, an accurate method for describing this parameter is important. Existing conformity ratios and indices used in radiosurgery are reviewed and criticized. It will be demonstrated that previously proposed measurements of conformity can, under certain conditions, give false perfect scores. A new conformity index is derived that gives an objective score of conformity for a treatment plan and gives no false scores. An analysis of five different treatment plans is made using both the existing scoring methods and the new conformity index.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Radiation dose-volume effects in radiation-induced rectal injury.

            The available dose/volume/outcome data for rectal injury were reviewed. The volume of rectum receiving >or=60 Gy is consistently associated with the risk of Grade >or=2 rectal toxicity or rectal bleeding. Parameters for the Lyman-Kutcher-Burman normal tissue complication probability model from four clinical series are remarkably consistent, suggesting that high doses are predominant in determining the risk of toxicity. The best overall estimates (95% confidence interval) of the Lyman-Kutcher-Burman model parameters are n = 0.09 (0.04-0.14); m = 0.13 (0.10-0.17); and TD(50) = 76.9 (73.7-80.1) Gy. Most of the models of late radiation toxicity come from three-dimensional conformal radiotherapy dose-escalation studies of early-stage prostate cancer. It is possible that intensity-modulated radiotherapy or proton beam dose distributions require modification of these models because of the inherent differences in low and intermediate dose distributions. Copyright 2010 Elsevier Inc. All rights reserved.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Volumetric modulated arc therapy for delivery of prostate radiotherapy: comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy.

              Volumetric modulated arc therapy (VMAT) is a novel form of intensity-modulated radiotherapy (IMRT) optimization that allows the radiation dose to be delivered in a single gantry rotation of up to 360 degrees , using either a constant dose rate (cdr-VMAT) or variable dose rate (vdr-VMAT) during rotation. The goal of this study was to compare VMAT prostate RT plans with three-dimensional conformal RT (3D-CRT) and IMRT plans. The 3D-CRT, five-field IMRT, cdr-VMAT, and vdr-VMAT RT plans were created for 10 computed tomography data sets from patients undergoing RT for prostate cancer. The parameters evaluated included the doses to organs at risk, equivalent uniform doses, dose homogeneity and conformality, and monitor units required for delivery of a 2-Gy fraction. The IMRT and both VMAT techniques resulted in lower doses to normal critical structures than 3D-CRT plans for nearly all dosimetric endpoints analyzed. The lowest doses to organs at risk and most favorable equivalent uniform doses were achieved with vdr-VMAT, which was significantly better than IMRT for the rectal and femoral head dosimetric endpoints (p < 0.05) and significantly better than cdr-VMAT for most bladder and rectal endpoints (p < 0.05). The vdr-VMAT and cdr-VMAT plans required fewer monitor units than did the IMRT plans (relative reduction of 42% and 38%, respectively; p = 0.005) but more than for the 3D-CRT plans (p = 0.005). The IMRT and VMAT techniques achieved highly conformal treatment plans. The vdr-VMAT technique resulted in more favorable dose distributions than the IMRT or cdr-VMAT techniques, and reduced the monitor units required compared with IMRT.
                Bookmark

                Author and article information

                Contributors
                georgy.kopanitsa@gmail.com
                Journal
                J Appl Clin Med Phys
                J Appl Clin Med Phys
                10.1002/(ISSN)1526-9914
                ACM2
                Journal of Applied Clinical Medical Physics
                John Wiley and Sons Inc. (Hoboken )
                1526-9914
                08 July 2014
                July 2014
                : 15
                : 4 ( doiID: 10.1002/acm2.2014.15.issue-4 )
                : 39-53
                Affiliations
                [ 1 ] Gomel Regional Oncology Center Gomel Republic of Belarus
                [ 2 ] Institute of Physics and Technology Tomsk Polytechnic University Tomsk Russia
                [ 3 ] Elekta GmbH Innsbruck Austria
                [ 4 ] Institute Cybernetic Center Tomsk Polytechnic University Tomsk Russia
                [ 5 ] Tomsk State University for Architecture and Building Tomsk Russia
                Author notes
                [*] [* ] a Corresponding author: Georgy Kopanitsa, Institute Cybernetic Center, Tomsk Polytechnic University, 634050 Lenina 30, Tomsk, Russia; phone: 0079528088099; fax: 0073822563865; email: georgy.kopanitsa@ 123456gmail.com

                Article
                ACM20039
                10.1120/jacmp.v15i4.4514
                5875496
                25207394
                50c0e8f1-8092-439b-b10a-e2f3a7a94f97
                © 2014 The Authors.

                This is an open access article under the terms of the http://creativecommons.org/licenses/by/3.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

                History
                : 06 May 2013
                : 11 February 2014
                Page count
                Figures: 4, Tables: 6, References: 28, Pages: 15, Words: 6594
                Categories
                Radiation Oncology Physics
                Radiation Oncology Physics
                Custom metadata
                2.0
                acm20039
                July 2014
                Converter:WILEY_ML3GV2_TO_NLMPMC version:version=5.3.4 mode:remove_FC converted:29.03.2018

                vmat,imrt,biologically based optimization,dose‐volume‐based optimization,plan comparison,prostate cancer,head and neck cancer

                Comments

                Comment on this article