3
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      The first 1-year-long estimate of the Paris region fossil fuel CO<sub>2</sub> emissions based on atmospheric inversion

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          <p><strong>Abstract.</strong> The ability of a Bayesian atmospheric inversion to quantify the Paris region's fossil fuel CO<sub>2</sub> emissions on a monthly basis, based on a network of three surface stations operated for 1 year as part of the CO<sub>2</sub>-MEGAPARIS experiment (August 2010–July 2011), is analysed. Differences in hourly CO<sub>2</sub> atmospheric mole fractions between the near-ground monitoring sites (CO<sub>2</sub> gradients), located at the north-eastern and south-western edges of the urban area, are used to estimate the 6<span class="thinspace"></span>h mean fossil fuel CO<sub>2</sub> emission. The inversion relies on the CHIMERE transport model run at 2<span class="thinspace"></span>km<span class="thinspace"></span> × <span class="thinspace"></span>2<span class="thinspace"></span>km horizontal resolution, on the spatial distribution of fossil fuel CO<sub>2</sub> emissions in 2008 from a local inventory established at 1<span class="thinspace"></span>km<span class="thinspace"></span> × <span class="thinspace"></span>1<span class="thinspace"></span>km horizontal resolution by the AIRPARIF air quality agency, and on the spatial distribution of the biogenic CO<sub>2</sub> fluxes from the C-TESSEL land surface model. It corrects a prior estimate of the 6<span class="thinspace"></span>h mean budgets of the fossil fuel CO<sub>2</sub> emissions given by the AIRPARIF 2008 inventory. We found that a stringent selection of CO<sub>2</sub> gradients is necessary for reliable inversion results, due to large modelling uncertainties. In particular, the most robust data selection analysed in this study uses only mid-afternoon gradients if wind speeds are larger than 3<span class="thinspace"></span>m<span class="thinspace"></span>s<sup>−1</sup> and if the modelled wind at the upwind site is within ±15° of the transect between downwind and upwind sites. This stringent data selection removes 92<span class="thinspace"></span>% of the hourly observations. Even though this leaves few remaining data to constrain the emissions, the inversion system diagnoses that their assimilation significantly reduces the uncertainty in monthly emissions: by 9<span class="thinspace"></span>% in November 2010 to 50<span class="thinspace"></span>% in October 2010. The inverted monthly mean emissions correlate well with independent monthly mean air temperature. Furthermore, the inverted annual mean emission is consistent with the independent revision of the AIRPARIF inventory for the year 2010, which better corresponds to the measurement period than the 2008 inventory. Several tests of the inversion's sensitivity to prior emission estimates, to the assumed spatial distribution of the emissions, and to the atmospheric transport modelling demonstrate the robustness of the measurement constraint on inverted fossil fuel CO<sub>2</sub> emissions. The results, however, show significant sensitivity to the description of the emissions' spatial distribution in the inversion system, demonstrating the need to rely on high-resolution local inventories such as that from AIRPARIF. Although the inversion constrains emissions through the assimilation of CO<sub>2</sub> gradients, the results are hampered by the improperly modelled influence of remote CO<sub>2</sub> fluxes when air masses originate from urbanised and industrialised areas north-east of Paris. The drastic data selection used in this study limits the ability to continuously monitor Paris fossil fuel CO<sub>2</sub> emissions: the inversion results for specific months such as September or November 2010 are poorly constrained by too few CO<sub>2</sub> measurements. The high sensitivity of the inverted emissions to the prior emissions' diurnal variations highlights the limitations induced by assimilating data only during the afternoon. Furthermore, even though the inversion improves the seasonal variation and the annual budget of the city's emissions, the assimilation of data during a limited number of suitable days does not necessarily yield robust estimates for individual months. These limitations could be overcome through a refinement of the data processing for a wider data selection, and through the expansion of the observation network.</p>

          Related collections

          Most cited references26

          • Record: found
          • Abstract: not found
          • Article: not found

          The LMDZ4 general circulation model: climate performance and sensitivity to parametrized physics with emphasis on tropical convection

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            A Physically-Based Scheme For The Urban Energy Budget In Atmospheric Models

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              The AROME-France Convective-Scale Operational Model

                Bookmark

                Author and article information

                Journal
                Atmospheric Chemistry and Physics
                Atmos. Chem. Phys.
                Copernicus GmbH
                1680-7324
                2016
                November 25 2016
                : 16
                : 22
                : 14703-14726
                Article
                10.5194/acp-16-14703-2016
                53abd348-ef00-4646-9257-1e39a0855c54
                © 2016

                https://creativecommons.org/licenses/by/3.0/

                History

                Comments

                Comment on this article