      Wearable Cardioverter‐Defibrillator in a Patient with Left Ventricular Noncompaction/Hypertrabeculation, Coronary Artery Disease, and Polyneuropathy

      case-report

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A 55‐year‐old Caucasian male with coronary heart disease was admitted because of dyspnea for 4 weeks. Echocardiography showed a dilated left ventricle with an ejection fraction of 34% and apical left ventricular hypertrabeculation/noncompaction with an apical thrombus. Neurologic examination revealed positional tremor and generally reduced tendon reflexes. During 8 weeks, his condition improved under pharmacotherapy. The patient was skeptical about implantable cardioverter‐defibrillator (ICD) and expected further improvement from pharmacotherapy. Thus, he received a wearable cardioverter‐defibrillator (WCD). We conclude that a WCD might be useful in noncompaction patients in whom improvement of systolic dysfunction is expected or who are skeptical about ICDs.

          Related collections

          Author and article information

          Journal
          Ann Noninvasive Electrocardiol
          Ann Noninvasive Electrocardiol
          10.1111/(ISSN)1542-474X
          ANEC
          Annals of Noninvasive Electrocardiology : The Official Journal of the International Society for Holter and Noninvasive Electrocardiology, Inc
          John Wiley and Sons Inc. (Hoboken )
          1082-720X
          1542-474X
          06 March 2014
          January 2015
          : 20
          : 1 ( doiID: 10.1111/anec.2015.20.issue-1 )
          : 79-81
          Affiliations
          [ 1 ] Hospital Rudolf Foundation Vienna Austria
          Author notes
          [*] [* ]Address for correspondence: Claudia Stöllberger, M.D., Steingasse 31/18, A‐1030 Wien, Österreich. Fax: +43 1 71165 2209; E‐mail: claudia.stoellberger@ 123456chello.at
          Article
          PMC6931510 PMC6931510 6931510 ANEC12155
          10.1111/anec.12155
          6931510
          24602189
          54148689-61cc-4ed4-8488-60caa5713273
          © 2014 Wiley Periodicals, Inc.
          History
          Page count
          Pages: 3
          Categories
          Case Report
          Case Reports
          Custom metadata
          2.0
          January 2015
          Converter:WILEY_ML3GV2_TO_JATSPMC version:5.7.3 mode:remove_FC converted:18.12.2019

          implantable cardioverter‐defibrillator,cardiomyopathy,sudden cardiac death,heart failure

          Comments

          Comment on this article