      Cooperative Three-View Imaging Optical Coherence Tomography for Intraoperative Vascular Evaluation

      , , , , , , ,
      Applied Sciences
      MDPI AG

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Real-time intraoperative optical coherence tomography (OTC) imaging of blood vessels after anastomosis operation can provide important information the vessel, such as patency, flow speed, and thrombosis morphology. Due to the strong scattering and absorption effect of blood, normal OCT imaging suffers from the problem of incomplete cross-sectional view of the vessel under investigation when the diameter is large. In this work, we present a novel cooperative three-view imaging spectral domain optical coherence tomography system for intraoperative exposed vascular imaging. Two more side views (left view and right view) were realized through a customized sample arm optical design and corresponding mechanical design and fabrication, which could generate cross-sectional images from three circumferential view directions to achieve a larger synthetic field of view (FOV). For each view, the imaging depth was 6.7 mm (in air) and the lateral scanning range was designed to be 3 mm. Therefore, a shared synthetic rectangle FOV of 3 mm × 3 mm was achieved through cooperative three view scanning. This multi-view imaging method can meet the circumferential imaging demands of vessels with an outer diameter less than 3 mm. Both phantom tube and rat vessel imaging confirmed the increased system FOV performance. We believe the intraoperative application of this cooperative three-imaging optical coherence tomography for objective vascular anastomosis evaluation can benefit patient outcomes in the future.

          Related collections

          Most cited references18

          • Record: found
          • Abstract: found
          • Article: not found

          Characterization of human atherosclerosis by optical coherence tomography.

          High-resolution visualization of atherosclerotic plaque morphology may be essential for identifying coronary plaques that cause acute coronary events. Optical coherence tomography (OCT) is an intravascular imaging modality capable of providing cross-sectional images of tissue with a resolution of 10 micro m. To date, OCT imaging has not been investigated in sufficient detail to assess its accuracy for characterizing atherosclerotic plaques. The aim of this study was to establish objective OCT image criteria for atherosclerotic plaque characterization in vitro. OCT images of 357 (diseased) atherosclerotic arterial segments obtained at autopsy were correlated with histology. OCT image criteria for 3 types of plaque were formulated by analysis of a subset (n=50) of arterial segments. OCT images of fibrous plaques were characterized by homogeneous, signal-rich regions; fibrocalcific plaques by well-delineated, signal-poor regions with sharp borders; and lipid-rich plaques by signal-poor regions with diffuse borders. Independent validation of these criteria by 2 OCT readers for the remaining segments (n=307) demonstrated a sensitivity and specificity ranging from 71% to 79% and 97% to 98% for fibrous plaques, 95% to 96% and 97% for fibrocalcific plaques, and 90% to 94% and 90% to 92% for lipid-rich plaques, respectively (overall agreement, kappa=0.83 to 0.84). The interobserver and intraobserver reliabilities of OCT assessment were high (kappa values of 0.88 and 0.91, respectively). Objective OCT criteria are highly sensitive and specific for characterizing different types of atherosclerotic plaques. These results represent an important step in validating this new intravascular imaging modality and will provide a basis for the interpretation of intracoronary OCT images obtained from patients.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography.

            We report the development of an optical technique for noninvasive imaging of in vivo blood flow dynamics and tissue structures with high spatial resolution (2-10 microm) in biological systems. The technique is based on optical Doppler tomography (ODT), which combines Doppler velocimetry with optical coherence tomography to measure blood flow velocity at discrete spatial locations. The exceptionally high resolution of ODT permits noninvasive in vivo imaging of both blood microcirculation and tissue structures surrounding the vessel, which has significance for biomedical research and clinical applications. Tomographic imaging of in vivo blood flow velocity in the chick chorioallantoic membrane and in rodent skin is demonstrated.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Long-range and wide field of view optical coherence tomography for in vivo 3D imaging of large volume object based on akinetic programmable swept source

              Current optical coherence tomography (OCT) imaging suffers from short ranging distance and narrow imaging field of view (FOV). There is growing interest in searching for solutions to these limitations in order to expand further in vivo OCT applications. This paper describes a solution where we utilize an akinetic swept source for OCT implementation to enable ~10 cm ranging distance, associated with the use of a wide-angle camera lens in the sample arm to provide a FOV of ~20 x 20 cm 2 . The akinetic swept source operates at 1300 nm central wavelength with a bandwidth of 100 nm. We propose an adaptive calibration procedure to the programmable akinetic light source so that the sensitivity of the OCT system over ~10 cm ranging distance is substantially improved for imaging of large volume samples. We demonstrate the proposed swept source OCT system for in vivo imaging of entire human hands and faces with an unprecedented FOV (up to 400 cm 2 ). The capability of large-volume OCT imaging with ultra-long ranging and ultra-wide FOV is expected to bring new opportunities for in vivo biomedical applications.
                Bookmark

                Author and article information

                Journal
                ASPCC7
                Applied Sciences
                Applied Sciences
                MDPI AG
                2076-3417
                September 2018
                September 04 2018
                : 8
                : 9
                : 1551
                Article
                10.3390/app8091551
                5444f86e-8e8b-4e3e-894e-cc4be5f914d2
                © 2018

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article