      Smartphone Application with Virtual Reality Goggles for the Reliable and Valid Measurement of Active Craniocervical Range of Motion

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Objective: This study aimed to determine the intra-rater and inter-rater reliability and validity of a hybrid device, combining virtual reality goggles, a magnetometer and an inclinometer application for smartphones, to measure craniocervical range. Summary of Background Data: Accurate evaluation of craniocervical range of motion is important for early detection of certain diseased conditions and monitoring the progress of interventions. The universal goniometer is widely used for the measurement but it requires experienced practitioners. Whether a combination of virtual reality goggles and smartphone applications can provide the same or better performance compared with the goniometer is still unknown. Methods: Forty-one healthy adults from the department of physical medicine and rehabilitation were recruited for craniocervical range examination (flexion, extension, side-bending to the right or left and rotating to the right or left) by using the hybrid device and universal goniometer. Using the hybrid device, repeated measurements were performed twice by a primary rater and once by a second rater. The primary rater also conducted a measurement using the universal goniometer in the same cohort. The intra-rater and inter-rater reliability (intra-class correlation coefficient (ICC)) were calculated using the two-way random effect model, whereas the validity was examined by the Pearson correlation coefficient and Bland-and-Altman plot. The interval between the first and second sessions of the measurement for intra-rater reliability was set at 30 min. Results: Excellent intra-rater (ICC ≥ 0.925) and inter-rater (ICC ≥ 0.880) reliability was noted for the hybrid device. The minimal detectable changes from intra-observer and inter-observer comparisons ranged between 4.12° and 7.42° in all six directions. The Bland-and-Altman plot revealed small mean differences (≤1.68°) between the hybrid device and universal goniometer. Both instruments had highly correlated measurements of craniocervical motion ( r values ≥ 0.918). Conclusion: For healthy participants, excellent intra-rater and inter-rater reliability was noted for the hybrid device, and the measurements were consistent with the universal goniometer measurements. Future studies are needed to examine whether the device can perform similarly for patients with neck disorders.

          Related collections

          Most cited references19

          • Record: found
          • Abstract: found
          • Article: not found

          The epidemiology of neck pain.

          Neck pain is becoming increasingly common throughout the world. It has a considerable impact on individuals and their families, communities, health-care systems, and businesses. There is substantial heterogeneity between neck pain epidemiological studies, which makes it difficult to compare or pool data from different studies. The estimated 1 year incidence of neck pain from available studies ranges between 10.4% and 21.3% with a higher incidence noted in office and computer workers. While some studies report that between 33% and 65% of people have recovered from an episode of neck pain at 1 year, most cases run an episodic course over a person's lifetime and, thus, relapses are common. The overall prevalence of neck pain in the general population ranges between 0.4% and 86.8% (mean: 23.1%); point prevalence ranges from 0.4% to 41.5% (mean: 14.4%); and 1 year prevalence ranges from 4.8% to 79.5% (mean: 25.8%). Prevalence is generally higher in women, higher in high-income countries compared with low- and middle-income countries and higher in urban areas compared with rural areas. Many environmental and personal factors influence the onset and course of neck pain. Most studies indicate a higher incidence of neck pain among women and an increased risk of developing neck pain until the 35-49-year age group, after which the risk begins to decline. The Global Burden of Disease 2005 Study is currently making estimates of the global burden of neck pain in relation to impairment and activity limitation, and results will be available in 2011. 2011 Elsevier Ltd. All rights reserved.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Short-term changes in neck pain, widespread pressure pain sensitivity, and cervical range of motion after the application of trigger point dry needling in patients with acute mechanical neck pain: a randomized clinical trial.

            Randomized clinical trial.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Clinimetric evaluation of active range of motion measures in patients with non-specific neck pain: a systematic review

              The study is to provide a critical analysis of the research literature on clinimetric properties of instruments that can be used in daily practice to measure active cervical range of motion (ACROM) in patients with non-specific neck pain. A computerized literature search was performed in Medline, Cinahl and Embase from 1982 to January 2007. Two reviewers independently assessed the clinimetric properties of identified instruments using a criteria list. The search identified a total of 33 studies, investigating three different types of measurement instruments to determine ACROM. These instruments were: (1) different types of goniometers/inclinometers, (2) visual estimation, and (3) tape measurements. Intra- and inter-observer reliability was demonstrated for the cervical range of motion instrument (CROM), Cybex electronic digital instrument (EDI-320) and a single inclinometer. The presence of agreement was assessed for the EDI-320 and a single inclinometer. The CROM received a positive rating for construct validity. When clinical acceptability is taken into account both the CROM and the single inclinometer can be considered appropriate instruments for measuring the active range of motion in patients with non-specific neck pain in daily practice. Reliability is the aspect most frequently evaluated. Agreement, validity and responsiveness are documented less frequently.
                Bookmark

                Author and article information

                Journal
                Diagnostics (Basel)
                Diagnostics (Basel)
                diagnostics
                Diagnostics
                MDPI
                2075-4418
                10 July 2019
                September 2019
                : 9
                : 3
                : 71
                Affiliations
                [1 ]Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Bei-Hu Branch 10845, Taiwan
                [2 ]Community and Geriatric Medicine Research Center, National Taiwan University Hospital, Bei-Hu Branch 10845, Taiwan
                [3 ]Department of Physical Medicine and Rehabilitation, National Taiwan University College of Medicine, Taipei 10048, Taiwan
                [4 ]Health Science and Wellness Center, National Taiwan University, Taipei 10617, Taiwan
                [5 ]Institute of Biomedical Sciences, Academia Sinica, Taipei 11574, Taiwan
                [6 ]Taiwan Mouse Clinic—National Comprehensive Mouse Phenotyping and Drug Testing Center, Academia Sinica, Taipei 11574, Taiwan
                Author notes
                [* ]Correspondence: dshan1121@ 123456yahoo.com.tw (D.-S.H.); chih@ 123456ibms.sinica.edu.tw (C.-C.C.)
                [†]

                These authors contributed equally to this manuscript.

                Author information
                https://orcid.org/0000-0002-7558-5651
                Article
                diagnostics-09-00071
                10.3390/diagnostics9030071
                6787724
                31295869
                55217f1d-0f6a-488c-b4ed-abd6f8acfd08
                © 2019 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 12 June 2019
                : 09 July 2019
                Categories
                Article

                goniometer,neck,rehabilitation
                goniometer, neck, rehabilitation