2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Two-year clinical outcomes of the NOBORI biolimus-eluting stents versus XIENCE/PROMUS everolimus-eluting stents in small vessel disease : BES vs. EES in Small Vessel Disease

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references25

          • Record: found
          • Abstract: found
          • Article: not found

          Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery.

          Preliminary reports of studies involving simple coronary lesions indicate that a sirolimus-eluting stent significantly reduces the risk of restenosis after percutaneous coronary revascularization. We conducted a randomized, double-blind trial comparing a sirolimus-eluting stent with a standard stent in 1058 patients at 53 centers in the United States who had a newly diagnosed lesion in a native coronary artery. The coronary disease in these patients was complex because of the frequent presence of diabetes (in 26 percent of patients), the high percentage of patients with longer lesions (mean, 14.4 mm), and small vessels (mean, 2.80 mm). The primary end point was failure of the target vessel (a composite of death from cardiac causes, myocardial infarction, and repeated percutaneous or surgical revascularization of the target vessel) within 270 days. The rate of failure of the target vessel was reduced from 21.0 percent with a standard stent to 8.6 percent with a sirolimus-eluting stent (P<0.001)--a reduction that was driven largely by a decrease in the frequency of the need for revascularization of the target lesion (16.6 percent in the standard-stent group vs. 4.1 percent in the sirolimus-stent group, P<0.001). The frequency of neointimal hyperplasia within the stent was also decreased in the group that received sirolimus-eluting stents, as assessed by both angiography and intravascular ultrasonography. Subgroup analyses revealed a reduction in the rates of angiographic restenosis and target-lesion revascularization in all subgroups examined. In this randomized clinical trial involving patients with complex coronary lesions, the use of a sirolimus-eluting stent had a consistent treatment effect, reducing the rates of restenosis and associated clinical events in all subgroups analyzed. Copyright 2003 Massachusetts Medical Society
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease.

            Restenosis after coronary stenting necessitates repeated percutaneous or surgical revascularization procedures. The delivery of paclitaxel to the site of vascular injury may reduce the incidence of neointimal hyperplasia and restenosis. At 73 U.S. centers, we enrolled 1314 patients who were receiving a stent in a single, previously untreated coronary-artery stenosis (vessel diameter, 2.5 to 3.75 mm; lesion length, 10 to 28 mm) in a prospective, randomized, double-blind study. A total of 652 patients were randomly assigned to receive a bare-metal stent, and 662 to receive an identical-appearing, slow-release, polymer-based, paclitaxel-eluting stent. Angiographic follow-up was prespecified at nine months in 732 patients. In terms of base-line characteristics, the two groups were well matched. Diabetes mellitus was present in 24.2 percent of patients; the mean reference-vessel diameter was 2.75 mm, and the mean lesion length was 13.4 mm. A mean of 1.08 stents (length, 21.8 mm) were implanted per patient. The rate of ischemia-driven target-vessel revascularization at nine months was reduced from 12.0 percent with the implantation of a bare-metal stent to 4.7 percent with the implantation of a paclitaxel-eluting stent (relative risk, 0.39; 95 percent confidence interval, 0.26 to 0.59; P<0.001). Target-lesion revascularization was required in 3.0 percent of the group that received a paclitaxel-eluting stent, as compared with 11.3 percent of the group that received a bare-metal stent (relative risk, 0.27; 95 percent confidence interval, 0.16 to 0.43; P<0.001). The rate of angiographic restenosis was reduced from 26.6 percent to 7.9 percent with the paclitaxel-eluting stent (relative risk, 0.30; 95 percent confidence interval, 0.19 to 0.46; P<0.001). The nine-month composite rates of death from cardiac causes or myocardial infarction (4.7 percent and 4.3 percent, respectively) and stent thrombosis (0.6 percent and 0.8 percent, respectively) were similar in the group that received a paclitaxel-eluting stent and the group that received a bare-metal stent. As compared with bare-metal stents, the slow-release, polymer-based, paclitaxel-eluting stent is safe and markedly reduces the rates of clinical and angiographic restenosis at nine months. Copyright 2004 Massachusetts Medical Society
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease.

              Previous studies have established the superiority of coronary everolimus-eluting stents over paclitaxel-eluting stents with respect to angiographic findings. However, these trials were not powered for superiority in clinical end points. We randomly assigned 3687 patients at 66 U.S. sites to receive everolimus-eluting stents or paclitaxel-eluting stents without routine follow-up angiography. The primary end point was the 1-year composite rate of target-lesion failure (defined as cardiac death, target-vessel myocardial infarction, or ischemia-driven target-lesion revascularization). Everolimus-eluting stents were superior to paclitaxel-eluting stents with respect to the primary end point of target-lesion failure (4.2% vs. 6.8%; relative risk, 0.62; 95% confidence interval, 0.46 to 0.82; P=0.001). Everolimus-eluting stents were also superior with respect to the major secondary end point of the 1-year rate of ischemia-driven target-lesion revascularization (P=0.001) and were noninferior with respect to the major secondary end point of the 1-year composite rate of cardiac death or target-vessel myocardial infarction (P<0.001 for noninferiority; P=0.09 for superiority). The 1-year rates of myocardial infarction and stent thrombosis were also lower with everolimus-eluting stents than with paclitaxel-eluting stents (1.9% vs. 3.1%, P=0.02 for myocardial infarction; 0.17% vs. 0.85%, P=0.004 for stent thrombosis). Target-lesion failure was consistently reduced with everolimus-eluting stents as compared with paclitaxel-eluting stents in 12 prespecified subgroups, except in the subgroup of patients with diabetes (6.4% vs. 6.9%, P=0.80). Everolimus-eluting stents, as compared with paclitaxel-eluting stents, resulted in reduced rates of target-lesion failure at 1 year, results that were consistent in all patients except those with diabetes, in whom the results were nonsignificantly different. (ClinicalTrials.gov number, NCT00307047.) 2010 Massachusetts Medical Society
                Bookmark

                Author and article information

                Journal
                Catheterization and Cardiovascular Interventions
                Cathet. Cardiovasc. Intervent.
                Wiley
                15221946
                November 2016
                November 2016
                December 28 2015
                : 88
                : 5
                : E132-E138
                Affiliations
                [1 ]Department of Cardiology; Kokura Memorial Hospital; Fukuoka Japan
                [2 ]Department of Biostatistics, School of Public Health; the University of Tokyo; Tokyo Japan
                Article
                10.1002/ccd.26360
                26708085
                567236a0-fe0f-4201-b44c-b4ff4fd74b92
                © 2015

                http://doi.wiley.com/10.1002/tdm_license_1.1

                History

                Comments

                Comment on this article