      Reproducibility of planar 123I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy in patients with heart failure

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          Despite its high prognostic value, widespread clinical implementation of 123I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy is hampered by a lack of validation and standardization. The purpose of this study was to assess the reliability of planar 123I-MIBG myocardial scintigraphy in patients with heart failure (HF).

          Methods

          Planar myocardial MIBG images of 70 HF patients were analysed by two experienced and one inexperienced observer. The reproducibility of early and delayed heart-to-mediastinum (H/M) ratios, as well as washout rate (WR) calculated by two different methods, was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman analysis. In addition, a subanalysis in patients with a very low H/M ratio (delayed H/M ratio <1.4) was performed. The delayed H/M ratio was also assessed using fixed-size oval and circular cardiac regions of interest (ROI).

          Results

          Intra- and interobserver analyses and experienced versus inexperienced observer analysis showed excellent agreement for the measured early and delayed H/M ratios and WR on planar 123I-MIBG images (the ICCs for the delayed H/M ratios were 0.98, 0.96 and 0.90, respectively). In addition, the WR without background correction resulted in higher reliability than the WR with background correction (the interobserver Bland-Altman 95 % limits of agreement were −2.50 to 2.16 and −10.10 to 10.14, respectively). Furthermore, the delayed H/M ratio measurements remained reliable in a subgroup of patients with a very low delayed H/M ratio (ICC 0.93 for the inter-observer analysis). Moreover, a fixed-size cardiac ROI could be used for the assessment of delayed H/M ratios, with good reliability of the measurement.

          Conclusion

          The present study showed a high reliability of planar 123I-MIBG myocardial scintigraphy in HF patients, confirming that MIBG myocardial scintigraphy can be implemented easily for clinical risk stratification in HF.

          Related collections

          Most cited references24

          • Record: found
          • Abstract: found
          • Article: not found

          Cardiac sympathetic denervation assessed with 123-iodine metaiodobenzylguanidine imaging predicts ventricular arrhythmias in implantable cardioverter-defibrillator patients.

          The purpose of this study was to evaluate whether 123-iodine metaiodobenzylguanidine (123-I MIBG) imaging predicts ventricular arrhythmias causing appropriate implantable cardioverter-defibrillator (ICD) therapy (primary end point) and the composite of appropriate ICD therapy or cardiac death (secondary end point). Although cardiac sympathetic denervation is associated with ventricular arrhythmias, limited data are available on the predictive value of sympathetic nerve imaging with 123-I MIBG on the occurrence of arrhythmias. Before ICD implantation, patients underwent 123-I MIBG and myocardial perfusion imaging. Early and late 123-I MIBG (planar and single-photon emission computed tomography [SPECT]) imaging was performed to assess cardiac innervation (heart-to-mediastinum ratio, cardiac washout rate, and 123-I MIBG SPECT defect score). Stress-rest myocardial perfusion imaging was performed to assess myocardial infarction and perfusion abnormalities (perfusion defect scores). During follow-up, appropriate ICD therapy and cardiac death were documented. One-hundred sixteen heart failure patients referred for ICD therapy were enrolled. During a mean follow-up of 23 +/- 15 months, appropriate ICD therapy (primary end point) was documented in 24 (21%) patients and appropriate ICD therapy or cardiac death (secondary end point) in 32 (28%) patients. Late 123-I MIBG SPECT defect score was an independent predictor for both end points. Patients with a large late 123-I MIBG SPECT defect (summed score >26) showed significantly more appropriate ICD therapy (52% vs. 5%, p < 0.01) and appropriate ICD therapy or cardiac death (57% vs. 10%, p < 0.01) than patients with a small defect (summed score
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Proposal for standardization of 123I-metaiodobenzylguanidine (MIBG) cardiac sympathetic imaging by the EANM Cardiovascular Committee and the European Council of Nuclear Cardiology.

            This proposal for standardization of (123)I-metaiodobenzylguanidine (iobenguane, MIBG) cardiac sympathetic imaging includes recommendations for patient information and preparation, radiopharmaceutical, injected activities and dosimetry, image acquisition, quality control, reconstruction methods, attenuation, scatter and collimator response compensation, data analysis and interpretation, reports, and image display. The recommendations are based on evidence coming from original or scientific studies whenever possible and as far as possible reflect the current state-of-the-art in cardiac MIBG imaging. The recommendations are designed to assist in the practice of performing, interpreting and reporting cardiac sympathetic imaging. The proposed standardization does not include clinical indications, benefits or drawbacks of cardiac sympathetic imaging, and does not address cost benefits or cost effectiveness; however, clinical settings of potential utility are mentioned. Standardization of MIBG cardiac sympathetic imaging should contribute to increasing its clinical applicability and integration into current nuclear cardiology practice.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Prognostic value of myocardial 123I-metaiodobenzylguanidine (MIBG) parameters in patients with heart failure: a systematic review.

              To derive a more precise estimate of the prognostic significance of myocardial 123I-metaiodobenzylguanidine (MIBG) parameters [early heart mediastinal ratio (H/M), late H/M, and myocardial washout] in heart failure (HF). Eighteen studies with a total of 1755 patients, stratifying survival, and cardiac events in patients with HF by MIBG, were eligible for analysis. The pooled hazard ratio (HR) estimates for cardiac death and cardiac events associated with washout showed no significant heterogeneity and were 1.72 [95%CI (confidence interval), 1.72-2.52; P = 0.006] and 1.08 (95%CI: 1.03-1.12; P or = 75%). Limiting the pooling to the qualitative best three studies rendered I2 insignificant (I2 = 0) and resulted in a pooled HR of late H/M for cardiac death of 1.82 (95%CI: 0.80-4.12; P = 0.15) and for cardiac events of 1.98 (95%CI: 1.57-2.50; P < 0.001). Our results indicate that patients with HF and decreased late H/M or increased myocardial MIBG washout have a worse prognosis compared with those with normal semi-quantitative myocardial MIBG parameters.
                Bookmark

                Author and article information

                Contributors
                +31-71-5262020 , +31-71-5266809 , c.e.veltman@lumc.nl
                Journal
                Eur J Nucl Med Mol Imaging
                Eur. J. Nucl. Med. Mol. Imaging
                European Journal of Nuclear Medicine and Molecular Imaging
                Springer-Verlag (Berlin/Heidelberg )
                1619-7070
                1619-7089
                13 July 2012
                13 July 2012
                October 2012
                : 39
                : 10
                : 1599-1608
                Affiliations
                [1 ]Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, The Netherlands
                [2 ]The Interuniversity Cardiology Institute of the Netherlands (ICIN), Utrecht, The Netherlands
                [3 ]Department of Nuclear Medicine, Leiden University Medical Center, Leiden, The Netherlands
                Article
                2180
                10.1007/s00259-012-2180-2
                3458210
                22790878
                56c2b5cb-4355-445f-9f41-40a74bc8a5e4
                © The Author(s) 2012
                History
                : 2 March 2012
                : 15 June 2012
                Categories
                Original Article
                Custom metadata
                © Springer-Verlag 2012

                Radiology & Imaging
                heart failure,planar mibg myocardial scintigraphy,delayed heart to mediastinum (h/m) ratio,region of interest (roi),reproducibility

                Comments

                Comment on this article