      Insulin degludec overdose in an adolescent with type 1 diabetes: proactive management including monitoring using the Freestyle Libre flash glucose monitoring system

      research-article

      Read this article at

      ScienceOpenPublisherPMC
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Summary

          An adolescent with type 1 diabetes and a history of self-harm, which included intentional overdoses and insulin omission, presented with an insulin degludec overdose. She had been commenced on the ultra-long-acting insulin, degludec, with the aim of reducing ketoacidosis episodes in response to intermittent refusal to take insulin. Insulin degludec was administered under supervision as an outpatient. Because it was anticipated that she would attempt a degludec overdose at some stage, the attending clinicians implemented a proactive management plan for this (and related) scenarios. This included long-term monitoring of interstitial glucose using the Abbott Freestyle Libre flash glucose monitor. The patient took a witnessed overdose of 242 units of degludec (usual daily dose, 32 units). She was hospitalised an hour later. Inpatient treatment was guided primarily by interstitial glucose results, with capillary and venous glucose tests used as secondary measures to assess the accuracy of interstitial glucose values. Four days of inpatient treatment was required. The patient was managed with high glycaemic loads of food and also intermittent intravenous dextrose. No hypoglycaemia was documented during the admission. In summary, while a degludec overdose may require several days of inpatient management, in situations where proactive management is an option and the dose administered is relatively modest, it may be possible to avoid significant hypoglycaemia. In addition, this case demonstrates that inpatient interstitial glucose monitoring may have a role in managing insulin overdose, especially in situations where the effect of the insulin overdose on glucose levels is likely to be prolonged.

          Learning points:
          • Degludec overdoses have a prolonged effect on blood glucose levels, but if the clinical situation allows for early detection and management, treatment may prove easier than that which is typically needed following overdoses of a similar dose of shorter acting insulins.

          • Inpatient real-time interstitial monitoring helped guide management, which in this context included the prescription of high dietary carbohydrate intake (patient led) and intravenous 10% dextrose (nurse led).

          • Use of inpatient interstitial glucose monitoring to guide therapy might be considered ‘off label’ use, thus, both staff and also patients should be aware of the limitations, as well as the benefits, of interstitial monitoring systems.

          • The Libre flash glucose monitor provided nurses with low cost, easy-to-use interstitial glucose results, but it is nevertheless advisable to check these results against conventional glucose tests, for example, capillary ‘finger-stick’ or venous glucose tests.

          Related collections

          Most cited references7

          • Record: found
          • Abstract: found
          • Article: not found

          Accuracy of flash glucose monitoring and continuous glucose monitoring technologies: Implications for clinical practice.

          Continuous glucose monitoring and flash glucose monitoring technologies measure glucose in the interstitial fluid and are increasingly used in diabetes care. Their accuracy, key to effective glycaemic management, is usually measured using the mean absolute relative difference of the interstitial fluid sensor compared to reference blood glucose readings. However, mean absolute relative difference is not standardised and has limitations. This review aims to provide a consensus opinion on assessing accuracy of interstitial fluid glucose sensing technologies. Mean absolute relative difference is influenced by glucose distribution and rate of change; hence, we express caution on the reliability of comparing mean absolute relative difference data from different study systems and conditions. We also review the pitfalls associated with mean absolute relative difference at different glucose levels and explore additional ways of assessing accuracy of interstitial fluid devices. Importantly, much data indicate that current practice of assessing accuracy of different systems based on individualised mean absolute relative difference results has limitations, which have potential clinical implications. Healthcare professionals must understand the factors that influence mean absolute relative difference as a metric for accuracy and look at additional assessments, such as consensus error grid analysis, when evaluating continuous glucose monitoring and flash glucose monitoring systems in diabetes care. This in turn will ensure that management decisions based on interstitial fluid sensor data are both effective and safe.
            • Record: found
            • Abstract: found
            • Article: not found

            A Systematic Review on Insulin Overdose Cases: Clinical Course, Complications and Treatment Options.

            A large overdose of insulin is a serious health matter. Information concerning administration and duration of intravenous (IV) glucose, other treatment options or complications besides hypoglycaemia following large insulin overdoses is not readily apparent from the literature. A systematic search, compilation and review of case reports on insulin overdoses, published 1986-2017, was performed in PubMed, EMBASE, Cochrane and PROSPERO databases. Of 1523 published articles, 45 cases of insulin overdoses were included with a total median insulin dose of 900 international units (IU) (range 26-4800 IU). Hospitalization occurred in 44 cases with a median hospitalization duration of 94 hr (range 12-721 hr), and one-third (n = 15) admitted to the intensive care unit. First-line treatment was IV glucose treatment in 95% of cases. Treatment options besides IV glucose that were reported beneficial included glucagon IV or intramuscular (IM), octreotide IV or IM, surgical excision, hydrocortisone IV and oral intake of complex carbohydrates. Prevalent complications were intermittent cerebral impairment (73%), hypokalaemia (49%), other electrolyte disturbances (42%), and hepatic disturbances (7%) and cardiac toxicity (e.g. cardiac arrhythmia) (9%). Long-term consequences were one case of lasting hypoglycaemic encephalopathy and one death. In conclusion, following large insulin overdoses, in-hospital admission and treatment with IV glucose may be needed for up to a week. Monitoring of electrolytes and hepatic and cardiac functions seems important. Several experimental treatment options may be considered in addition to glucose administration. With appropriate pre- and in-hospital treatment, cases with severe hypoglycaemia and neurologic complications may have a favourable outcome.
              • Record: found
              • Abstract: found
              • Article: not found

              The role of the new basal insulin analogs in addressing unmet clinical needs in people with type 1 and type 2 diabetes.

              Despite improvements in anti-hyperglycemic therapies, there are many unmet clinical needs that hinder successful glycemic control in people being treated with current basal insulin analogs.

                Author and article information

                Journal
                Endocrinol Diabetes Metab Case Rep
                Endocrinol Diabetes Metab Case Rep
                EDM
                Endocrinology, Diabetes & Metabolism Case Reports
                Bioscientifica Ltd (Bristol )
                2052-0573
                01 June 2018
                2018
                : 2018
                : 18-0044
                Affiliations
                [1 ]Department of Endocrinology and Diabetes , Canterbury District Health Board, Christchurch, New Zealand
                [2 ]Department of Medicine , University of Otago Christchurch, Christchurch, New Zealand
                Author notes
                Correspondence should be addressed to H Lunt Email helen.lunt@ 123456cdhb.health.nz
                Article
                EDM180044
                10.1530/EDM-18-0044
                5987182
                57b071f9-a27b-4256-a2c6-2687aec9ed2e
                © 2018 The authors

                This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License.

                History
                : 27 March 2018
                : 03 May 2018
                Categories
                Novel Treatment

                Comments

                Comment on this article

                Related Documents Log