0
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Electromyographical analysis and comparison of selected abdominal training devices with a traditional crunch.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The present study compared the muscle activity elicited by selected abdominal training devices with muscle activity elicited by a traditional crunch. Forty-six adults participated in the study. The exercise devices tested included the Ab-ONE, Perfect Abs Roller, Ab Scissor, Ab Swing, 6SecondAbs, and the Torso Track. For those devices with variable resistances, all were tested at their high resistance setting. Surface electromyography (EMG) was recorded from the upper and lower portions of the rectus abdominis and the external oblique during each repetition. EMG values were analyzed using repeated measures analyses of variance (ANOVA) and pairwise comparisons. EMG measurements for each abdominal muscle analyzed were highly reliable and differed significantly across the exercises tested. Muscle activity for the upper and lower portions of the rectus abdominis for a normal crunch was lower than for the Ab-ONE, the same as for the Perfect Abs Roller, and higher than for the Ab Scissor, Ab Swing, 6SecondAbs, and Torso Track. External oblique muscle activity for a traditional crunch was higher than for the Perfect Abs Roller and did not differ from the other devices. These results support previous findings that portable abdominal devices are most effective if they not only mimic the mechanics of a traditional crunch, but also provide external resistance to increase involvement of the abdominal musculature.

          Related collections

          Author and article information

          Journal
          J Strength Cond Res
          Journal of strength and conditioning research
          Ovid Technologies (Wolters Kluwer Health)
          1064-8011
          1064-8011
          Feb 2005
          : 19
          : 1
          Affiliations
          [1 ] Department of Kinesiology, Occidental College, Los Angeles, California 90041, USA. simplyft@oxy.edu
          Article
          R-14864
          10.1519/R-14864.1
          15705027
          57c5204b-c8c0-42b3-b962-857cb7372a2b
          History

          Comments

          Comment on this article