10
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Noninvasive assessment of regional ventilation in the human lung using oxygen-enhanced magnetic resonance imaging.

      Nature medicine
      Humans, Lung, pathology, Magnetic Resonance Imaging, methods, Oxygen, Pulmonary Ventilation

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The imaging of regional ventilation in the lungs is essential for the evaluation of a variety of pathological conditions, such as emphysema, pneumonia and pulmonary embolism. We propose a novel approach for ventilation scanning, using magnetic resonance imaging (MRI) and inhaled molecular oxygen as a contrast agent, that directly depicts transfer of oxygen across the alveolus into the pulmonary vasculature. Molecular oxygen is only weakly paramagnetic but produces substantial signal changes in the lungs because of their large surface area. Ventilation defects were shown in a patient with bullous emphysema, and ventilation-perfusion mismatches were shown in two patients with pulmonary embolism.

          Related collections

          Most cited references11

          • Record: found
          • Abstract: found
          • Article: not found

          Projection reconstruction techniques for reduction of motion effects in MRI.

          Projection reconstruction (PR) techniques are shown to have intrinsic advantages over spin-warp (2DFT) methods with respect to diminished artifacts from respiratory motion. The benefits result from (1) portrayal of artifacts as radial streaks, with the amplitude smallest near the moving elements; (2) streak deployment perpendicular to the direction of motion of moving elements and often residing outside the anatomic boundaries of the subject; (3) inherent signal averaging of low spatial frequencies from oversampling of central k-space data. In addition, respiratory-ordered view angle (ROVA) acquisition is found to diminish residual streaking significantly by reducing interview inconsistencies. Comparisons of 2DFT and PR acquisitions are made with and without ROVA. Reconstructions from magnitude-only projections are found to have increased streaks from motion-induced phase shifts.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            MR Imaging with Hyperpolarized3He Gas

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Human lung air spaces: potential for MR imaging with hyperpolarized He-3.

              Two healthy volunteers who had inhaled approximately 0.75 L of laser-polarized helium-3 gas underwent magnetic resonance imaging at 1.5 T with fast gradient-echo pulse sequences and small flip angles ( < 10 degrees). Thick-section (20 mm) coronal images, time-course data (30 images collected every 1.8 seconds), and thin-section (6 mm) images were acquired. Subjects were able to breathe the gas (12% polarization) without difficulty. Thick-section images were of good quality and had a signal-to-noise ratio (S/N) of 32:1 near the surface coil and 16:1 farther away. The time images showed regional differences, which indicated potential value for quantitation. High-resolution images showed greater detail and a S/N of approximately 6:1.
                Bookmark

                Author and article information

                Journal
                8898751
                10.1038/nm1196-1236

                Chemistry
                Humans,Lung,pathology,Magnetic Resonance Imaging,methods,Oxygen,Pulmonary Ventilation
                Chemistry
                Humans, Lung, pathology, Magnetic Resonance Imaging, methods, Oxygen, Pulmonary Ventilation

                Comments

                Comment on this article