      Highly Sensitive Compact Force Sensor Based on Microfiber Bragg Grating

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references11

          • Record: found
          • Abstract: found
          • Article: not found

          Novel contact force sensor incorporated in irrigated radiofrequency ablation catheter predicts lesion size and incidence of steam pop and thrombus.

          An open-irrigated radiofrequency (RF) ablation catheter was developed to measure contact force (CF). Three optical fibers measure microdeformation of the catheter tip. The purpose of this study was to (1) validate the accuracy of CF sensor (CFS) (bench test); and (2) determine the relationship between CF and tissue temperatures, lesion size, steam pop, and thrombus during RF ablation using a canine thigh muscle preparation. CFS measurements (total 1409) from 2 catheters in 3 angles (perpendicular, parallel, and 45 degrees ) were compared with a certified balance (range, 0 to 50 g). CFS measurements correlated highly (R(2) > or =0.988; mean error, < or =1.0 g). In 10 anesthetized dogs, a skin cradle over the thigh muscle was superfused with heparinized blood at 37 degrees C. A 7F catheter with 3.5-mm saline-irrigated electrode and CFS (Endosense) was held perpendicular to the muscle at CF of 2, 10, 20, 30, and 40 g. RF was delivered (n=100) for 60 seconds at 30 or 50 W (irrigation 17 or 30 mL/min). Tissue temperature (3 and 7 mm depths), lesion size, thrombus, and steam pop increased significantly with increasing CF at each RF power. Lesion size was greater with applications of lower power (30 W) and greater CF (30 to 40 g) than at high power (50 W) with lower CF (2 to 10 g). This novel ablation catheter, which accurately measures CF, confirmed CF is a major determinant of RF lesion size. Steam pop and thrombus incidence also increases with CF. CFS in an open-irrigated ablation catheter that may optimize the selection of RF power and application time to maximize lesion formation and reduce the risk of steam pop and thrombus.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            MRI-Compatible Fiber-Optic Force Sensors for Catheterization Procedures

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              FBG-type sensor for simultaneous measurement of force (or displacement) and temperature based on bilateral cantilever beam

                Bookmark

                Author and article information

                Journal
                IEEE Photonics Technology Letters
                IEEE Photon. Technol. Lett.
                Institute of Electrical and Electronics Engineers (IEEE)
                1041-1135
                1941-0174
                April 2012
                April 2012
                : 24
                : 8
                : 700-702
                Article
                10.1109/LPT.2012.2187049
                586ce217-0e66-422b-9c5c-bddba07eadb1
                © 2012
                History

                Comments

                Comment on this article