      Trends Supporting the In-Field Use of Wearable Inertial Sensors for Sport Performance Evaluation: A Systematic Review

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Recent technological developments have led to the production of inexpensive, non-invasive, miniature magneto-inertial sensors, ideal for obtaining sport performance measures during training or competition. This systematic review evaluates current evidence and the future potential of their use in sport performance evaluation. Articles published in English (April 2017) were searched in Web-of-Science, Scopus, Pubmed, and Sport-Discus databases. A keyword search of titles, abstracts and keywords which included studies using accelerometers, gyroscopes and/or magnetometers to analyse sport motor-tasks performed by athletes (excluding risk of injury, physical activity, and energy expenditure) resulted in 2040 papers. Papers and reference list screening led to the selection of 286 studies and 23 reviews. Information on sport, motor-tasks, participants, device characteristics, sensor position and fixing, experimental setting and performance indicators was extracted. The selected papers dealt with motor capacity assessment (51 papers), technique analysis (163), activity classification (19), and physical demands assessment (61). Focus was placed mainly on elite and sub-elite athletes (59%) performing their sport in-field during training (62%) and competition (7%). Measuring movement outdoors created opportunities in winter sports (8%), water sports (16%), team sports (25%), and other outdoor activities (27%). Indications on the reliability of sensor-based performance indicators are provided, together with critical considerations and future trends.

          Related collections

          Most cited references358

          • Record: found
          • Abstract: found
          • Article: not found

          Monitoring Training Load to Understand Fatigue in Athletes

          Many athletes, coaches, and support staff are taking an increasingly scientific approach to both designing and monitoring training programs. Appropriate load monitoring can aid in determining whether an athlete is adapting to a training program and in minimizing the risk of developing non-functional overreaching, illness, and/or injury. In order to gain an understanding of the training load and its effect on the athlete, a number of potential markers are available for use. However, very few of these markers have strong scientific evidence supporting their use, and there is yet to be a single, definitive marker described in the literature. Research has investigated a number of external load quantifying and monitoring tools, such as power output measuring devices, time-motion analysis, as well as internal load unit measures, including perception of effort, heart rate, blood lactate, and training impulse. Dissociation between external and internal load units may reveal the state of fatigue of an athlete. Other monitoring tools used by high-performance programs include heart rate recovery, neuromuscular function, biochemical/hormonal/immunological assessments, questionnaires and diaries, psychomotor speed, and sleep quality and quantity. The monitoring approach taken with athletes may depend on whether the athlete is engaging in individual or team sport activity; however, the importance of individualization of load monitoring cannot be over emphasized. Detecting meaningful changes with scientific and statistical approaches can provide confidence and certainty when implementing change. Appropriate monitoring of training load can provide important information to athletes and coaches; however, monitoring systems should be intuitive, provide efficient data analysis and interpretation, and enable efficient reporting of simple, yet scientifically valid, feedback.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Nonlinear Complementary Filters on the Special Orthogonal Group

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The reliability of MinimaxX accelerometers for measuring physical activity in Australian football.

              To assess the reliability of triaxial accelerometers as a measure of physical activity in team sports. Eight accelerometers (MinimaxX 2.0, Catapult, Australia) were attached to a hydraulic universal testing machine (Instron 8501) and oscillated over two protocols (0.5 g and 3.0 g) to assess within- and between device reliability. A static assessment was also conducted. Secondly, 10 players were instrumented with two accelerometers during Australian football matches. The vector magnitude was calculated, expressed as Player load and assessed for reliability using typical error (TE) ± 90% confidence intervals (CI), and expressed as a coefficient of variation (CV%). The smallest worthwhile difference (SWD) in Player load was calculated to determine if the device was capable of detecting differences in physical activity. Laboratory: Within- (Dynamic: CV 0.91 to 1.05%; Static: CV 1.01%) and between-device (Dynamic: CV 1.02 to 1.04%; Static: CV 1.10%) reliability was acceptable across each test. Field: The between-device reliability of accelerometers during Australian football matches was also acceptable (CV 1.9%). The SWD was 5.88%. The reliability of the MinimaxX accelerometer is acceptable both within and between devices under controlled laboratory conditions, and between devices during field testing. MinimaxX accelerometers can be confidently utilized as a reliable tool to measure physical activity in team sports across multiple players and repeated bouts of activity. The noise (CV%) of Player load was lower than the signal (SWD), suggesting that accelerometers can detect changes or differences in physical activity during Australian football.
                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel)
                sensors
                Sensors (Basel, Switzerland)
                MDPI
                1424-8220
                15 March 2018
                March 2018
                : 18
                : 3
                : 873
                Affiliations
                [1 ]Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), University of Rome “Foro Italico”, Piazza L. De Bosis 6, 00135 Rome, Italy; elena.bergamini@ 123456uniroma4.it (E.B.); giuseppe.vannozzi@ 123456uniroma4.it (G.V.)
                [2 ]Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, Piazza L. De Bosis 6, 00135 Rome, Italy
                [3 ]Department of Electrical, Electronic, and Information Engineering “Guglielmo Marconi”, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy; silvia.fantozzi@ 123456unibo.it
                [4 ]Health Sciences and Technologies—Interdepartmental Centre for Industrial Research, University of Bologna, Viale Risorgimento 2, 40136 Bologna, Italy
                Author notes
                [* ]Correspondence valentina.camomilla@ 123456uniroma4.it ; Tel.: +39-06-36733-522
                Author information
                https://orcid.org/0000-0002-7452-120X
                https://orcid.org/0000-0002-9055-3981
                https://orcid.org/0000-0002-0660-7204
                https://orcid.org/0000-0002-2359-6076
                Article
                sensors-18-00873
                10.3390/s18030873
                5877384
                29543747
                58e44782-f41f-4e62-a7b3-edca7565e9de
                © 2018 by the authors.

                Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ( http://creativecommons.org/licenses/by/4.0/).

                History
                : 15 February 2018
                : 11 March 2018
                Categories
                Review

                Biomedical engineering
                magneto-inertial sensors,biomechanics,sports,accelerometer,mems,gyroscope,performance assessment,athlete,motion analysis

                Comments

                Comment on this article