9
views
0
recommends
+1 Recommend
1 collections
    0
    shares

      International Journal of COPD (submit here)

      This international, peer-reviewed Open Access journal by Dove Medical Press focuses on pathophysiological processes underlying Chronic Obstructive Pulmonary Disease (COPD) interventions, patient focused education, and self-management protocols. Sign up for email alerts here.

      39,063 Monthly downloads/views I 2.893 Impact Factor I 5.2 CiteScore I 1.16 Source Normalized Impact per Paper (SNIP) I 0.804 Scimago Journal & Country Rank (SJR)

      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Lack of paradoxical bronchoconstriction after administration of tiotropium via Respimat ® Soft Mist™ Inhaler in COPD

      research-article

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Bronchoconstriction has been reported in asthma and chronic obstructive pulmonary disease (COPD) patients after administration of some aqueous inhalation solutions. We investigated the incidence of this event during long-term clinical trials of tiotropium delivered via Respimat ® Soft Mist™ Inhaler (SMI). We retrospectively analyzed pooled data from two identical Phase III clinical trials, in which 1990 patients with COPD received 48 weeks’ treatment with once-daily tiotropium (5 or 10 μg) or placebo inhaled via Respimat ® SMI. We recorded the incidence of bronchospasm and of a range of respiratory events that could suggest bronchoconstriction during the first 30 minutes after inhalation of study treatment on each of the eight test days. No patients reported bronchospasm. Six patients (0.3%) reported a combination of at least two events suggestive of bronchoconstriction, and 21 (1.1%) reported either rescue medication use or a respiratory adverse event. Asymptomatic falls in forced expiratory volume in one second (FEV 1) of ≥15% were recorded on all test days, with no change in incidence over time, and affected 8.2% of those in the tiotropium groups and 14.5% of those on placebo. In COPD patients receiving long-term treatment with tiotropium 5 or 10 μg via Respimat ® SMI, no bronchospasm was recorded, and the number of events possibly indicative of paradoxical bronchoconstriction was very low.

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          A review of the development of Respimat Soft Mist Inhaler.

          Respimat Soft Mist Inhaler (SMI) is a new generation inhaler from Boehringer Ingelheim developed for use with respiratory drugs. The device functions by forcing a metered dose of drug solution through a unique and precisely engineered nozzle (the uniblock), producing two fine jets of liquid that converge at a pre-set angle. The collision of these two jets generates the soft mist. The soft mist contains a high fine particle fraction of approximately 65 to 80%. This is higher than aerosol clouds from conventional portable inhaler devices, such as pressurised metered dose inhalers (pMDIs) and dry powder inhalers (DPIs). In addition, the relatively long generation time of the aerosol cloud (approximately 1.5s) facilitates co-ordination of inhalation and actuation--a major problem with pMDIs. These features, together with the slow velocity of the soft mist, result in larger amounts of the drug reaching the lungs and less being deposited in the oropharynx compared with either pMDIs or DPIs. Generation of the soft mist from Respimat SMI is purely mechanical, so propellants are not necessary. The innovative design of Respimat SMI, using water-based drug formulations, ensures patients receive consistent and reliable doses of the drug with each actuation. The device was initially tested in scintigraphic lung deposition studies and produced encouraging results when compared with the chlorofluorocarbon-based pMDI (CFC-MDI). Subsequent clinical studies have confirmed that Respimat SMI is effective and safe in delivering bronchodilators to patients with asthma or chronic obstructive pulmonary disease.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Comparison of the aerosol velocity and spray duration of Respimat Soft Mist inhaler and pressurized metered dose inhalers.

            Apart from particle size distribution, spray velocity is one of the most important aerosol characteristics that influence lung deposition of inhaled drugs. The time period over which the aerosol is released (spray duration) is also important for coordination of inhalation. Respimat Soft Mist Inhaler (SMI) is a new generation, propellant-free inhaler that delivers drug to the lung much more efficiently than pressurised metered dose inhalers (pMDIs). The objective of this study was to compare the velocity and spray duration of aerosol clouds produced by Respimat SMI with those from a variety of chlorofluorocarbon (CFC) and hydrofluoroalkane (HFA) pMDIs. All inhalers contained solutions or suspensions of bronchodilators. A videorecording method was used to determine the aerosol velocity. For spray duration, the time for generation of the Soft Mist by Respimat SMI was initially determined using three different methods (videorecording [techniques A and B], laser light diffraction and rotating disc). Videorecording was then used to compare the spray duration of Respimat SMI with those from the other inhalers. The Soft Mist produced by Respimat SMI moved much more slowly and had a more prolonged duration than aerosol clouds from pMDIs (mean velocity at a 10-cm distance from the nozzle: Respimat SMI, 0.8 m/sec; pMDIs, 2.0-8.4 m/sec; mean duration: Respimat SMI, 1.5 sec; pMDIs, 0.15-0.36 sec). These characteristics should result in improved lung and reduced oropharyngeal deposition, and are likely to simplify coordination of inhaler actuation and inhalation compared with pMDIs.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Efficacy and safety of tiotropium Respimat® SMI in COPD in two 1-year randomized studies

              Two 1-year studies evaluated the long-term efficacy and safety of tiotropium 5 or 10 μg versus placebo, inhaled via the Respimat® Soft Mist™ Inhaler (SMI). The two studies were combined and had 4 co-primary endpoints (trough FEV1 response, Mahler Transition Dyspnea Index [TDI] and St George’s Respiratory Questionnaire scores all at week 48, and COPD exacerbations per patient-year). A total of 1990 patients with COPD participated (mean FEV1: 1.09 L). The mean trough FEV1 response of tiotropium 5 or 10 μg relative to placebo was 127 or 150 mL, respectively (both P < 0.0001). The COPD exacerbation rate was significantly lower with tiotropium 5 μg (RR = 0.78; P = 0.002) and tiotropium 10 μg (RR = 0.73; P = 0.0008); the health-related quality of life and Mahler TDI co-primary endpoints were significantly improved with both doses (both P < 0.0001). Adverse events were generally balanced except anticholinergic class effects, which were more frequent with active treatment. Fatal events occurred in 2.4% (5 μg), 2.7% (10 μg), and 1.6% (placebo) of patients; these differences were not significant. Tiotropium Respimat® SMI 5 μg demonstrated sustained improvements in patients with COPD relative to placebo and similar to the 10 μg dose but with a lower frequency of anticholinergic adverse events.
                Bookmark

                Author and article information

                Journal
                Int J Chron Obstruct Pulmon Dis
                International Journal of COPD
                International Journal of Chronic Obstructive Pulmonary Disease
                Dove Medical Press
                1176-9106
                1178-2005
                2011
                2011
                26 April 2011
                : 6
                : 245-251
                Affiliations
                [1 ]Divisions of Pulmonary and Critical Care, University of Ottawa, Ottawa, ON, Canada;
                [2 ]Boehringer Ingelheim Limited, Bracknell, England, UK;
                [3 ]Division of Pulmonology, Department of Medicine, University of Cape Town, Cape Town, South Africa
                Author notes
                Correspondence: Rick Hodder, Divisions of Pulmonary and Critical Care, The Ottawa Hospital, 1053 Carling Avenue, Ottawa, Ontario, Canada, Tel +1 613 761 4130, Fax +1 613 761 4152, Email rhodder@ 123456toh.on.ca .
                Article
                copd-6-245
                10.2147/COPD.S16094
                3144844
                21814460
                5c7ddf58-220d-49dd-8505-d51a90f1bce8
                © 2011 Hodder et al, publisher and licensee Dove Medical Press Ltd.

                This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.

                History
                : 22 April 2011
                Categories
                Original Research

                Respiratory medicine
                inhalation device,bronchoconstriction,copd,tiotropium
                Respiratory medicine
                inhalation device, bronchoconstriction, copd, tiotropium

                Comments

                Comment on this article