      A large area plastic scintillation detector with 4-corner-readout

      Preprint

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A 760 \(\times\) 760 \(\times\) 30 mm\(^3\) plastic scintillation detector viewed by photomultiplier tubes (PMTs) from four corners has been developed, and the detector has been tested with cosmic rays and \(\gamma\) rays. A position-independent effective time T\(_{eff}\) has been found, indicating this detector can be used as a TOF detector. The hit position can also be reconstructed by the time from four corners. A TOF resolution of 236 ps and a position resolution of 48 mm have been achieved, and the detection efficiency has also been investigated.