16
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Safety and efficacy of epithelium removal and transepithelial corneal collagen crosslinking for keratoconus.

      1 , 2 , 3
      Eye (London, England)

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This review aims to assess the efficacy and safety of epithelial removal (ER) and transepithelial (TE) corneal collagen crosslinking (CXL) for the treatment of keratoconus. We used MEDLINE to identify all ER and TE CXL studies on keratoconic eyes (n≥20, follow-up ≥12 months). Ex vivo and studies for non-keratoconus indications or in conjunction with other procedures were excluded. Data on uncorrected (UDVA) and corrected (CDVA) distance visual acuity, refractive cylinder, maximum keratometry (Kmax), and adverse events were collected at the latest follow-up and 1 year. Only one randomised controlled trial (RCT) qualified inclusion. Forty-four ER and five TE studies were included. For logMAR UDVA, CDVA, mean spherical equivalent, refractive cylinder and Kmax, at latest follow-up 81, 85, 93, 62, and 93% ER studies vs 66.7, 80, 75, 33, and 40% TE studies reported improvement, respectively. Whereas at 1 year, 90, 59, and 91% ER studies vs 80, 50, and 25% TE studies reported improvement, respectively. The majority of studies showed reduced pachymetry in both groups. Treatment failure, retreatment rates, and conversion to transplantation were reported to be up to 33, 8.6, and 6.25%, respectively, in ER studies only. Stromal oedema, haze, keratitis, and scarring were only reported in ER studies, whereas endothelial cell counts remained variable in both groups. Both ER and TE studies showed improvement in visual acuity, refractive cylinder but Kmax worsened in most TE studies. Adverse events were reported more with ER studies. This review calls for more high quality ER and TE studies with comparable parameters for further assessment of safety and efficacy.

          Related collections

          Author and article information

          Journal
          Eye (Lond)
          Eye (London, England)
          1476-5454
          0950-222X
          Jan 2015
          : 29
          : 1
          Affiliations
          [1 ] Department of Ophthalmology, Queen Mary's Hospital, King's College Hospital NHS Foundation Trust, London, UK.
          [2 ] Cochrane Eyes and Vision Group, Department of Epidemiology, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA.
          [3 ] Sussex Eye Hospital, Brighton and Sussex University Hospitals NHS Trust, Brighton, UK.
          Article
          eye2014230
          10.1038/eye.2014.230
          25277300
          5ead96f0-99f4-4fa3-929f-1ff481afa4ca
          History

          Comments

          Comment on this article