      Evaluation of dimensional accuracy for different complete edentulous impressions immersed in different disinfectant solutions

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Objective:

          The aim of this study was to evaluate the effects of two different disinfectant solutions’ immersion on the dimensional accuracy of different complete edentulous impressions.

          Materials and Methods:

          A specific custom-made metallic cast template was constructed and used for making both 120 alginate and zinc oxide eugenol (ZOE) paste impressions (60 for each). Disinfectants with 1% sodium hypochlorite and 2% glutaraldehyde were used for 10 and 60 min immersion of both impressions. After immersion time, the impressions were used for constructing 120 completely edentulous master stone models and divided into different groups according to the study. An electronic caliper was used for dimensional accuracy measurements of the casts. The data were collected and statistically analyzed according to the independent paired sample t-test at statistically significant level P < 0 05. One-way ANOVA test was used to compare between significant different groups.

          Results:

          There is no statistically significant difference in dimensional accuracy of alginate and ZOE paste impressions as disinfection with 1% sodium hypochlorite and 2% glutaraldehyde for 10 min and ZOE paste impressions for 60 min, where there is statistically significant difference in alginate impressions dimensional accuracy as disinfection with 1% sodium hypochlorite and 2% glutaraldehyde for 60 min.

          Conclusions:

          Possibility of ZOE impressions paste disinfected with 1% sodium hypochlorite and 2% glutaraldehyde for 10 or 60 min, not affecting on dimensional stability, while alginate impressions, only 10 min immersion in disinfectant not affecting the dimensional stability.

          Related collections

          Most cited references28

          • Record: found
          • Abstract: found
          • Article: not found

          Infection control recommendations for the dental office and the dental laboratory. ADA Council on Scientific Affairs and ADA Council on Dental Practice.

          (1996)
          This report is based on the recommendations of the Centers for Disease Control and Prevention and other publications in the medical and dental literature. The recommendations here, which have been accepted by the ADA Council on Scientific Affairs and the ADA Council on Dental Practice, are intended to offer general guidance for dental offices and laboratories on infection control. They are not intended to establish a standard of care or industry custom, nor are they intended to deprive the dentist of the ability to exercise his or her professional judgment.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts.

            This study primarily investigated the effect of disinfection procedures (Perform and sodium hypochlorite) on the dimensional accuracy and surface quality of four irreversible hydrocolloid impression materials and the resultant gypsum casts. The antibacterial efficacy of the procedures was also studied. Dimensional accuracy was determined from the mean percentage deviation of six measurements taken from casts made from disinfected impressions compared with corresponding measurements from the master model and controls. Statistical analysis of data was determined by analysis of variance. Surface quality was determined using a stainless steel test block in accordance with ISO 1563. The dimensional accuracy of the impression materials tested were of a comparable standard following disinfection. The surface quality of casts taken from Blueprint Cremix impressions were unaffected by the disinfection procedures. The remaining impression materials studied showed greater surface deterioration on casts following disinfection with sodium hypochlorite than immersion in Perform. All disinfection procedures selected proved appropriate for antibacterial purposes. Individual analysis of impression materials is required to determine their suitability to a given disinfection protocol.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Dimensional stability and detail reproduction of irreversible hydrocolloid and elastomeric impressions disinfected by immersion.

              Because irreversible hydrocolloid impressions imbibe blood and saliva, immersion rather than spray disinfection may be more effective. Polyether has been shown to be dimensionally sensitive to immersion disinfection. The aim of this study was to determine whether irreversible hydrocolloid and polyether impressions could be disinfected by immersion without sacrificing accuracy and surface quality. Impressions were made of a master mandibular arch containing a crown preparation. Changes between the master and working casts were assessed. Irreversible hydrocolloids (Jeltrate; Palgaflex), a polyether (Impregum F), and an addition silicone (President) were used. Disinfectants were an iodophor (Biocide), a glyoxal glutaraldehyde (Impresept de), and a phenol glutaraldehyde (Sporicidin). The control was without disinfection. Casts were formed in Type IV gypsum. The roughness of working dies was also recorded and an analysis of variance was used for statistical evaluation. Results. Casts from disinfected irreversible hydrocolloid and elastomeric impressions maintained accuracy for anteroposterior and cross arch dimensions where differences from the master was less than 0.1%. Buccolingual and mesiodistal dimensions of working dies (disinfected and control) were 6 to 8 microm larger than the master for addition silicones and 11 to 16 pm for polyethers. The occlusogingival dimension of dies for control and disinfected polyether was 9 pm longer than the master compared with -3 microm for addition silicone. The range of mean surface roughness of working dies made from irreversible hydrocolloids was 1.4 to 1.7 microm and ranged from 0.5 to 0.7 microm for elastomeric impressions. Conclusion. Immersion disinfection of Jeltrate material with iodophor and Palgaflex material with glyoxal glutaraldehyde produced casts and dies as accurate as the control. Control and disinfected elastomeric impression produced dies as clinically accurate and smooth as the master. Disinfection of irreversible hydrocolloid impressions with the glyoxal and phenol glutaraldehyde produced a surface smoother than controls.
                Bookmark

                Author and article information

                Journal
                Eur J Dent
                Eur J Dent
                EJD
                European Journal of Dentistry
                Medknow Publications & Media Pvt Ltd (India )
                1305-7456
                1305-7464
                Apr-Jun 2017
                : 11
                : 2
                : 242-249
                Affiliations
                [1 ]Department of Removable Prosthodontics, Al-Farabi Collages, KSA
                [2 ]Department of Removable Prosthodontics, Alazhar Univeristy, Cairo, Egypt
                Author notes
                Correspondence: Dr. Hussein Abdelfattah Ismail Email: hussien_eldwash@ 123456yahoo.com
                Article
                EJD-11-242
                10.4103/ejd.ejd_268_16
                5502573
                5ed806b7-9311-4c64-86f5-3ae322b80f79
                Copyright: © 2017 European Journal of Dentistry

                This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.

                History
                Categories
                Original Article

                Dentistry
                dimensional accuracy,disinfection,final impressions,glutaraldehyde,sodium hypochlorite
                Dentistry
                dimensional accuracy, disinfection, final impressions, glutaraldehyde, sodium hypochlorite

                Comments

                Comment on this article