6
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Emergency assessment of patients with acute abdominal pain using low-dose CT with iterative reconstruction: a comparative study

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references30

          • Record: found
          • Abstract: found
          • Article: not found

          Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study.

          The purpose of this study was to evaluate the image noise, low-contrast resolution, image quality, and spatial resolution of adaptive statistical iterative reconstruction in low-dose body CT. Adaptive statistical iterative reconstruction was used to scan the American College of Radiology phantom at the American College of Radiology reference value and at one-half that value (12.5 mGy). Test objects in low- and high-contrast and uniformity modules were evaluated. Low-dose CT with adaptive statistical iterative reconstruction was then tested on 12 patients (seven men, five women; average age, 67.5 years) who had previously undergone routine-dose CT. Two radiologists blinded to scanning technique evaluated images of the same patients obtained with routine-dose CT and low-dose CT with and without adaptive statistical iterative reconstruction. Image noise, low-contrast resolution, image quality, and spatial resolution were graded on a scale of 1 (best) to 4 (worst). Quantitative noise measurements were made on clinical images. In the phantom, low- and high-contrast and uniformity assessments showed no significant difference between routine-dose imaging and low-dose CT with adaptive statistical iterative reconstruction. In patients, low-dose CT with adaptive statistical iterative reconstruction was associated with CT dose index reductions of 32-65% compared with routine imaging and had the least noise both quantitatively and qualitatively (p < 0.05). Low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT had identical results for low-contrast resolution and nearly identical results for overall image quality (grade 2.1-2.2). Spatial resolution was better with routine-dose CT (p = 0.004). These preliminary results support body CT dose index reductions of 32-65% when adaptive statistical iterative reconstruction is used. Studies with larger statistical samples are needed to confirm these findings.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            CT dose reduction and dose management tools: overview of available options.

            In the past decade, the tremendous advances in computed tomography (CT) technology and applications have increased the clinical utilization of CT, creating concerns about individual and population doses of ionizing radiation. Scanner manufacturers have subsequently implemented several options to appropriately manage or reduce the radiation dose from CT. Modulation of the x-ray tube current during scanning is one effective method of managing the dose. However, the distinctions between the various tube current modulation products are not clear from the product names or descriptions. Depending on the scanner model, the tube current may be modulated according to patient attenuation or a sinusoidal-type function. The modulation may be fully preprogrammed, implemented in near-real time by using a feedback mechanism, or achieved with both preprogramming and a feedback loop. The dose modulation may occur angularly around the patient, along the long axis of the patient, or both. Finally, the system may allow use of one of several algorithms to automatically adjust the current to achieve the desired image quality. Modulation both angularly around the patient and along the z-axis is optimal, but the tube current must be appropriately adapted to patient size for diagnostic image quality to be achieved. (c) RSNA, 2006.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              National trends in CT use in the emergency department: 1995-2007.

              To identify nationwide trends and factors associated with the use of computed tomography (CT) in the emergency department (ED). This study was exempt from institutional review board approval. Data from the 1995-2007 National Hospital Ambulatory Medical Care Survey were used to evaluate the numbers and percentages of ED visits associated with CT. A mean of 30 044 visits were sampled each year. Data were also subcategorized according to multiple patient and hospital characteristics. The Rao-Scott χ(2) test was performed to determine whether CT use was similar across subpopulations. Data were evaluated according to exponential and logistic growth models. From 1995 to 2007, the number of ED visits that included a CT examination increased from 2.7 million to 16.2 million, constituting a 5.9-fold increase and a compound annual growth rate of 16.0%. The percentage of visits associated with CT increased from 2.8% to 13.9%, constituting a 4.9-fold increase and a compound annual growth rate of 14.2%. The exponential growth model provided the best fit for the trend in CT use. CT use was greater in older patients, white patients, patients admitted to the hospital, and patients at facilities in metropolitan regions. By the end of the study period, the top chief complaints among those who underwent CT were abdominal pain, headache, and chest pain. The percentage of patient visits associated with CT for all evaluated chief complaints increased-most substantially among those who underwent CT for flank, abdominal, or chest pain. Use of CT has increased at a higher rate in the ED than in other settings. The overall use of CT had not begun to taper by 2007. © RSNA, 2010
                Bookmark

                Author and article information

                Journal
                European Radiology
                Eur Radiol
                Springer Nature
                0938-7994
                1432-1084
                August 2017
                January 12 2017
                August 2017
                : 27
                : 8
                : 3300-3309
                Article
                10.1007/s00330-016-4712-9
                608114a5-311a-4cdb-834e-9dcc192d081d
                © 2017

                http://www.springer.com/tdm

                History

                Comments

                Comment on this article