      De novo topology optimization of total ossicular replacement prostheses

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          <p xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" class="first" id="d1408026e123">Conductive hearing loss, due to middle ear pathologies or traumas, affects more than 5% of the population worldwide. Passive prostheses to replace the ossicular chain mainly rely on piston-like titanium and/or hydroxyapatite devices, which in the long term suffer from extrusion. Although the basic shape of such devices always consists of a base for contact with the eardrum and a stem to have mechanical connection with the residual bony structures, a plethora of topologies have been proposed, mainly to help surgical positioning. In this work, we optimize the topology of a total ossicular replacement prosthesis, by maximizing the global stiffness and under the smallest possible volume constraint that ensures material continuity. This investigation optimizes the prosthesis topology in response to static displacement loads with amplitudes that normally occur during sound stimulation in a frequency range between 100 Hz and 10 kHz. Following earlier studies, we discuss how the presence and arrangement of holes on the surface of the prosthesis plate in contact with the umbo affect the overall geometry. Finally, we validate the designs through a finite-element model, in which we assess the prosthesis performance upon dynamic sound pressure loads by considering four different constitutive materials: titanium, cortical bone, silk, and collagen/hydroxyapatite. The results show that the selected prostheses present, almost independently of their constitutive material, a vibroacustic behavior close to that of the native ossicular chain, with a slight almost constant positive shift that reaches a maximum of ≈5 dB close to 1 kHz. This work represents a reference for the development of a new generation of middle ear prostheses with non-conventional topologies for fabrication via additive manufacturing technologies or ultraprecision machining in order to create patient-specific devices to recover from conductive hearing loss. </p>

          Related collections

          Author and article information

          Journal
          Journal of the Mechanical Behavior of Biomedical Materials
          Journal of the Mechanical Behavior of Biomedical Materials
          Elsevier BV
          17516161
          November 2019
          November 2019
          : 103541
          Article
          10.1016/j.jmbbm.2019.103541
          31786510
          60949ea8-0e32-43e3-bcb7-819eb3bb221f
          © 2019

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article