      Visceral adipose tissue quantification using Lunar Prodigy.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A dual-energy X-ray absorptiometry (DXA) application to measure visceral adipose tissue (VAT) in the android region of a total body DXA scan has recently been developed. This new application, CoreScan, has been validated on the Lunar iDXA (GE Healthcare, Madison, WI) densitometer against volumetric computed tomography. The geometric assumptions underlying the CoreScan model are the same on the Prodigy (GE Healthcare, Madison, WI) densitometer. However, differences between the peak X-ray voltage and detector array configurations may lead to differences in VAT quantification. The purpose of this study was to evaluate the agreement of Prodigy and iDXA CoreScan values and to characterize differences in VAT precision between the instruments. Data from volunteers with paired Prodigy and iDXA measurements were used to define empirical adjustments to the VAT algorithm parameters (n=59) and validate performance on Prodigy (n=62). Prodigy VAT measurements were highly correlated to iDXA (r=0.984). The mean of the Prodigy-iDXA VAT volume differences was -13.8cm³ with a 95% confidence interval of -45 to +17cm³. The Bland-Altman 95% limits of agreement for the 2 methods were -252 to +224cm³. Measurement of short-term precision showed that measurement error variance on iDXA was smaller (p<0.01) than Prodigy (coefficient of variance: 7.3% vs 9.8%). Precision results are in agreement with previous reports on the differences between Prodigy and iDXA for body composition measures. Prodigy and iDXA measures of VAT are similar, but the lower precision of the Prodigy may require investigators to target larger changes in VAT.

          Related collections

          Author and article information

          Journal
          J Clin Densitom
          Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry
          Elsevier BV
          1094-6950
          1094-6950
          November 15 2012
          : 16
          : 1
          Affiliations
          [1 ] GE Healthcare, Madison, WI, USA. ergundavid@gmail.com
          Article
          S1094-6950(12)00216-8
          10.1016/j.jocd.2012.09.002
          23148876
          60ab27a2-d199-4255-a219-38b0f69e3345
          History

          Comments

          Comment on this article