      Impact of improved attenuation correction on 18F-FDG PET/MR hybrid imaging of the heart

      research-article
      1 , * , 2 , 1 , 3
      PLoS ONE
      Public Library of Science

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          The aim of this study was to evaluate and quantify the effect of improved attenuation correction (AC) including bone segmentation and truncation correction on 18F-Fluordesoxyglucose cardiac positron emission tomography/magnetic resonance (PET/MR) imaging.

          Methods

          PET data of 32 cardiac PET/MR datasets were reconstructed with three different AC-maps (1. Dixon-VIBE only, 2. HUGE truncation correction and bone segmentation, 3. MLAA). The Dixon-VIBE AC-maps served as reference of reconstructed PET data. 17-segment short-axis polar plots of the left ventricle were analyzed regarding the impact of each of the three AC methods on PET quantification in cardiac PET/MR imaging. Non-AC PET images were segmented to specify the amount of truncation in the Dixon-VIBE AC-map serving as a reference. All AC-maps were evaluated for artifacts.

          Results

          Using HUGE + bone AC results in a homogeneous gain of ca. 6% and for MLAA 8% of PET signal distribution across the myocardium of the left ventricle over all patients compared to Dixon-VIBE AC only. Maximal relative differences up to 18% were observed in segment 17 (apex). The body volume truncation of -12.7 ± 7.1% compared to the segmented non-AC PET images using the Dixon-VIBE AC method was reduced to -1.9 ± 3.9% using HUGE and 7.8 ± 8.3% using MLAA. In each patient, a systematic overestimation in AC-map volume was observed when applying MLAA. Quantitative impact of artifacts showed regional differences up to 6% within single segments of the myocardium.

          Conclusions

          Improved AC including bone segmentation and truncation correction in cardiac PET/MR imaging is important to ensure best possible diagnostic quality and PET quantification. The results exhibited an overestimation of AC-map volume using MLAA, while HUGE resulted in a more realistic body contouring. Incorporation of bone segmentation into the Dixon-VIBE AC-map resulted in homogeneous gain in PET signal distribution across the myocardium. The majority of observed AC-map artifacts did not significantly affect the quantitative assessment of the myocardium.

          Related collections

          Most cited references34

          • Record: found
          • Abstract: found
          • Article: not found

          Attenuation correction for a combined 3D PET/CT scanner.

          In this work we demonstrate the proof of principle of CT-based attenuation correction of 3D positron emission tomography (PET) data by using scans of bone and soft tissue equivalent phantoms and scans of humans. This method of attenuation correction is intended for use in a single scanner that combines volume-imaging (3D) PET with x-ray computed tomography (CT) for the purpose of providing accurately registered anatomical localization of structures seen in the PET image. The goal of this work is to determine if we can perform attenuation correction of the PET emission data using accurately aligned CT attenuation information. We discuss possible methods of calculating the PET attenuation map at 511 keV based on CT transmission information acquired from 40 keV through 140 keV. Data were acquired on separate CT and PET scanners and were aligned using standard image registration procedures. Results are presented on three of the attenuation calculation methods: segmentation, scaling, and our proposed hybrid segmentation/scaling method. The results are compared with those using the standard 3D PET attenuation correction method as a gold standard. We demonstrate the efficacy of our proposed hybrid method for converting the CT attenuation map from an effective CT photon energy of 70 keV to the PET photon energy of 511 keV. We conclude that using CT information is a feasible way to obtain attenuation correction factors for 3D PET.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Whole-Body PET/MR Imaging: Quantitative Evaluation of a Novel Model-Based MR Attenuation Correction Method Including Bone.

            In routine whole-body PET/MR hybrid imaging, attenuation correction (AC) is usually performed by segmentation methods based on a Dixon MR sequence providing up to 4 different tissue classes. Because of the lack of bone information with the Dixon-based MR sequence, bone is currently considered as soft tissue. Thus, the aim of this study was to evaluate a novel model-based AC method that considers bone in whole-body PET/MR imaging.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Simultaneous reconstruction of activity and attenuation in time-of-flight PET.

              In positron emission tomography (PET) and single photon emission tomography (SPECT), attenuation correction is necessary for quantitative reconstruction of the tracer distribution. Previously, several attempts have been made to estimate the attenuation coefficients from emission data only. These attempts had limited success, because the problem does not have a unique solution, and severe and persistent "cross-talk" between the estimated activity and attenuation distributions was observed. In this paper, we show that the availability of time-of-flight (TOF) information eliminates the cross-talk problem by destroying symmetries in the associated Fisher information matrix. We propose a maximum-a-posteriori reconstruction algorithm for jointly estimating the attenuation and activity distributions from TOF PET data. The performance of the algorithm is studied with 2-D simulations, and further illustrated with phantom experiments and with a patient scan. The estimated attenuation image is robust to noise, and does not suffer from the cross-talk that was observed in non-TOF PET. However, some constraining is still mandatory, because the TOF data determine the attenuation sinogram only up to a constant offset.
                Bookmark

                Author and article information

                Contributors
                Role: Formal analysisRole: InvestigationRole: MethodologyRole: SoftwareRole: ValidationRole: VisualizationRole: Writing – original draft
                Role: InvestigationRole: MethodologyRole: ValidationRole: Writing – review & editing
                Role: InvestigationRole: Project administrationRole: SupervisionRole: Writing – review & editing
                Role: Editor
                Journal
                PLoS One
                PLoS ONE
                plos
                plosone
                PLoS ONE
                Public Library of Science (San Francisco, CA USA )
                1932-6203
                25 March 2019
                2019
                : 14
                : 3
                : e0214095
                Affiliations
                [1 ] High-Field and Hybrid MR Imaging, University Hospital Essen, University Duisburg-Essen, Essen, Germany
                [2 ] Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
                [3 ] Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen, Germany
                Ente Ospedaliero Cantonale, SWITZERLAND
                Author notes

                Competing Interests: The authors have declared that no competing interests exist.

                Author information
                http://orcid.org/0000-0002-7761-775X
                Article
                PONE-D-18-31953
                10.1371/journal.pone.0214095
                6433217
                30908507
                60f580f0-9078-4897-9925-f5c27d952fec
                © 2019 Lindemann et al

                This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

                History
                : 6 November 2018
                : 6 March 2019
                Page count
                Figures: 7, Tables: 1, Pages: 16
                Funding
                The authors received no specific funding for this work.
                Categories
                Research Article
                Research and Analysis Methods
                Imaging Techniques
                Neuroimaging
                Positron Emission Tomography
                Biology and Life Sciences
                Neuroscience
                Neuroimaging
                Positron Emission Tomography
                Medicine and Health Sciences
                Diagnostic Medicine
                Diagnostic Radiology
                Tomography
                Positron Emission Tomography
                Research and Analysis Methods
                Imaging Techniques
                Diagnostic Radiology
                Tomography
                Positron Emission Tomography
                Medicine and Health Sciences
                Radiology and Imaging
                Diagnostic Radiology
                Tomography
                Positron Emission Tomography
                Medicine and Health Sciences
                Diagnostic Medicine
                Diagnostic Radiology
                Bone Imaging
                Research and Analysis Methods
                Imaging Techniques
                Diagnostic Radiology
                Bone Imaging
                Medicine and Health Sciences
                Radiology and Imaging
                Diagnostic Radiology
                Bone Imaging
                Biology and Life Sciences
                Anatomy
                Cardiovascular Anatomy
                Heart
                Cardiac Ventricles
                Medicine and Health Sciences
                Anatomy
                Cardiovascular Anatomy
                Heart
                Cardiac Ventricles
                Biology and Life Sciences
                Anatomy
                Cardiovascular Anatomy
                Heart
                Myocardium
                Medicine and Health Sciences
                Anatomy
                Cardiovascular Anatomy
                Heart
                Myocardium
                Medicine and Health Sciences
                Diagnostic Medicine
                Diagnostic Radiology
                Magnetic Resonance Imaging
                Research and Analysis Methods
                Imaging Techniques
                Diagnostic Radiology
                Magnetic Resonance Imaging
                Medicine and Health Sciences
                Radiology and Imaging
                Diagnostic Radiology
                Magnetic Resonance Imaging
                Research and Analysis Methods
                Imaging Techniques
                Medicine and Health Sciences
                Diagnostic Medicine
                Diagnostic Radiology
                Pulmonary Imaging
                Research and Analysis Methods
                Imaging Techniques
                Diagnostic Radiology
                Pulmonary Imaging
                Medicine and Health Sciences
                Radiology and Imaging
                Diagnostic Radiology
                Pulmonary Imaging
                Biology and Life Sciences
                Anatomy
                Biological Tissue
                Soft Tissues
                Medicine and Health Sciences
                Anatomy
                Biological Tissue
                Soft Tissues
                Custom metadata
                All relevant data are within the paper and its Supporting Information files.

                Uncategorized
                Uncategorized

                Comments

                Comment on this article