      Automatic Static Threshold Perimetry Is Useful for Estimating the Effects of Laser Photocoagulation on Diabetic Maculopathy

      research-article

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Focal photocoagulation was performed on 18 eyes in 18 diabetes patients; a visual acuity test, fluorescein angiography and automated static threshold perimetry by Octopus automated static perimetry (program 31) were conducted before and 1, 3 and 6 months after krypton laser photocoagulation. Central field sensitivity and total loss were measured by automated static threshold perimetry. Group A (13 eyes) had a total loss of less than 150 dB. In these subjects, mild fluorescein leakage was detected within the area of the vascular arcade. In group B (5 eyes) with a total loss of greater than 150 dB, diffuse fluorescein leakage was also detected outside the vascular arcade. The central field sensitivity was reduced in 2 eyes of group B. The total loss worsened in 8 eyes of group A (61.5%) and 5 eyes of group B (100%). Inspection of photographs gave the impression that the degree of fluorescein leakage and the area of the avascular zone on fluorescein angiography accorded with total loss, thus suggesting that total loss reflects visual functions better than visual acuity or central field sensitivity. Therefore, automated static threshold perimetry appears to be a useful method for estimating visual functions after photocoagulation in diabetic maculopathy patients.

          Related collections

          Author and article information

          Journal
          ORE
          Ophthalmic Res
          10.1159/issn.0030-3747
          Ophthalmic Research
          S. Karger AG
          0030-3747
          1423-0259
          1998
          August 1998
          12 June 1998
          : 30
          : 4
          : 207-215
          Affiliations
          Department of Ophthalmology, National Defense Medical College, Tokorozawa, Japan
          Article
          55477 Ophthalmic Res 1998;30:207–215
          10.1159/000055477
          9667051
          6188d3cb-fbc9-4130-bea7-c6c296abbcf9
          © 1998 S. Karger AG, Basel

          Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

          History
          Page count
          Figures: 7, References: 22, Pages: 9
          Categories
          Original Paper

          Vision sciences,Ophthalmology & Optometry,Pathology
          Octopus automated static perimetry,Total loss,Krypton laser photocoagulation,Diabetic maculopathy,Central Sensitivity