      Etched multimode microfiber knot-type loop interferometer refractive index sensor.

      The Review of scientific instruments

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We propose a novel refractive index sensor based on multimode microfiber knot-type loop (NL) interferometer. The middle portion (~5 cm) of a 15 cm long multimode fiber is etched in 48% hydrofluoric acid to reduce its diameter to ~12 μm. A NL of diameter <1 mm is made from the etched fiber. The ends of etched fiber are spliced with single-mode fibers for launching and detecting light from the NL interferometer. The NL introduces path differences to produce interferometric spectra with free spectral range ~16 nm. The spectrum shifts as the surrounding refractive index of the loop is changed by adding chemicals. We observe the highest sensitivity of the NL interferometer ~172 nm/RIU (refractive index unit) at a refractive index value 1.370 as obtained experimentally using commonly available chemicals. The design could be used as simple, low cost, and highly sensitive biological and chemical sensor. © 2011 American Institute of Physics