      Silicone Oil: Different Physical Proprieties and Clinical Applications

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Silicone oils are important tools in vitreoretinal surgery because they have the ability to displace aqueous humor from the retinal surface, maintaining the adhesion between retina and retinal pigment epithelium. To understand this capability, it is important to know the silicone oil characteristics. Herein, we report first on the main chemical-physical proprieties and then we review the clinical applications of the current silicone oil which is lighter than water with particular reference to their indications with small gauge vitrectomy. Finally, we describe the surgical techniques to inject and remove this type of silicone oil. In the summary of this paper, we explain why silicone oils are today increasingly used and why their introduction has improved the prognosis of several retinal diseases. In fact, having different types of silicone oils allows us to choose the appropriate endotamponade for every single case.

          Related collections

          Most cited references39

          • Record: found
          • Abstract: found
          • Article: not found

          Complications associated with the use of silicone oil in 150 eyes after retina-vitreous surgery.

          Complicated retinal detachments (RDs) were successfully managed in 150 eyes of 170 consecutive patients by one surgeon (JLF) using silicone oil in conjunction with modern pars plana vitrectomy. Long-term postoperative complications were observed between 6 months and 5 years of follow-up. Cataracts developed in all phakic eyes and all corneas with oil-endothelial touch showed band keratopathy within 6 months. Recurrent detachments were noted in 22% of eyes during silicone oil tamponade and occurred in 13% of eyes after the oil had been removed. Other complications associated with the use of oil for vitreous surgery included pupillary block glaucoma (3%), closure of the inferior iridectomy (14%), fibrous epiretinal and subretinal proliferations (15%), pain (5%), and subconjunctival deposits of oil (3%). Without exception, within a period of 1 year the intraocular silicone oil showed some degree of emulsification, suggesting that the physicochemical characteristics of the oil injected may be an important variable in long-term complications.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Proliferative vitreoretinopathy: an overview.

            Proliferative vitreoretinopathy (PVR) is still the most common cause of failure of surgery for rhegmatogenous retinal detachment, despite the substantial effort that has been devoted to better understanding and managing this condition during the past 25 years. Basic research has indicated that PVR represents scarring, the end stage of the wound-healing process that occurs after retinal detachment surgery. Medical treatment has been directed toward preventing inflammation, the first phase of the wound healing process, and inhibiting cell proliferation, the second phase. The 1983 Retina Society classification was modified in 1989 by the Silicone Study Group, whose classification differentiates between posterior and anterior forms of PVR and recognizes three patterns of proliferation: diffuse, focal, and subretinal. The anterior form has a worse prognosis than the posterior form, and its treatment requires more complex surgical procedures. In this review, risk factors and pathobiology of PVR are discussed, and management of PVR of various degrees of severity are considered.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Silicone oil in the repair of complex retinal detachments. A prospective observational multicenter study.

              This study aimed to report anatomic and visual acuity outcomes and complications after 1000-centistoke silicone oil was used as a retinal tamponade for the treatment of complex retinal detachments. Prospective observational multicenter study conducted at community and university-based ophthalmology clinics. The study cohort consisted of 2439 patients (2573 eyes) treated for complex retinal detachments associated with cytomegalovirus (CMV) necrotizing retinitis or a non-CMV etiology, including proliferative diabetic retinopathy, giant retinal tears, proliferative vitreoretinopathy, or ocular trauma. Vitrectomy surgery was performed for complex retinal detachment with 1000-centistoke silicone oil as the retinal tamponade. Anatomic outcomes were complete retinal attachment and macular attachment. Visual acuity outcomes were ambulatory vision (> or = 4/200) and preservation of preoperative visual acuity. Complications were rates of secondary intraocular pressure elevation (> or = 30 mmHg), hypotony (< or = 5 mmHg), corneal opacification (including band keratopathy, corneal edema, and corneal abrasions), oil emulsification, and cataract. Outcomes were assessed 6, 12, and 24 months after surgery. At the 6-month examination, the retina was completely attached in 178 (78%) of 228 CMV eyes and in 855 (70%) of 1219 non-CMV eyes. The macula was attached in 216 (95%) of 228 and 1062 (89%) of 1189 CMV and non-CMV eyes, respectively. Ambulatory vision was noted in 151 (65%) of 234 CMV eyes and in 480 (38%) of 1251 non-CMV eyes. Visual acuity was preserved in 106 (46%) of 230 and 1035 (84%) of 1229 CMV and non-CMV eyes, respectively. The corresponding rates of complications for CMV and non-CMV eyes were: elevated intraocular pressure, 0 (0%) of 196 and 35 (3%) of 1196; hypotony, 11 (6%) of 196 and 228 (19%) of 1196; corneal opacity, 13 (6%) of 229 and 326 (26%) of 1248; emulsification, 3 (1%) of 211 and 29 (3%) of 959; and cataract in phakic eyes, 118 (64%) of 185 and 50 (63%) of 80. Retinal reattachment was achieved in the majority of eyes using vitrectomy and silicone oil retinal tamponade. Complication rates generally were less frequent in CMV eyes, but follow-up was shorter in this group of patients, largely because of reduced life expectancy. Cataract frequently developed in phakic eyes of study patients. Use of 1000-centistoke silicone oil can be considered in the management of complex retinal detachments associated with multiple etiologies.
                Bookmark

                Author and article information

                Journal
                Biomed Res Int
                Biomed Res Int
                BMRI
                BioMed Research International
                Hindawi Publishing Corporation
                2314-6133
                2314-6141
                2014
                11 June 2014
                : 2014
                : 502143
                Affiliations
                U.O. Chirurgia Oftalmica, Azienda Ospedaliero Universitaria Pisana (AOUP), Via Paradisa 2, 56124 Pisa, Italy
                Author notes
                *Francesco Barca: barcaf@ 123456hotmail.com

                Academic Editor: Mario R. Romano

                Article
                10.1155/2014/502143
                4071776
                25013785
                625460b4-113f-4d99-a6f0-12447873d200
                Copyright © 2014 Francesco Barca et al.

                This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 12 March 2014
                : 18 May 2014
                Categories
                Review Article

                Comments

                Comment on this article