      History of blood gas analysis. VI. Oximetry

      ,
      Journal of Clinical Monitoring
      Springer Science and Business Media LLC

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Oximetry, the measurement of hemoglobin oxygen saturation in either blood or tissue, depends on the Lambert-Beer relationship between light transmission and optical density. Shortly after Bunsen and Kirchhoff invented the spectrometer in 1860, the oxygen transport function of hemoglobin was demonstrated by Stokes and Hoppe-Seyler, who showed color changes produced by aeration of hemoglobin solutions. In 1932 in Göttingen, Germany, Nicolai optically recorded the in vivo oxygen consumption of a hand after circulatory occlusion. Kramer showed that the Lambert-Beer law applied to hemoglobin solutions and approximately to whole blood, and measured saturation by the transmission of red light through unopened arteries. Matthes in Leipzig, Germany, built the first apparatus to measure ear oxygen saturation and introduced a second wavelength (green or infrared) insensitive to saturation to compensate for blood volume and tissue pigments. Millikan built a light-weight ear "oximeter" during World War II to train pilots for military aviation. Wood added a pneumatic cuff to obtain a bloodless zero. Brinkman and Zijlstra in Groningen, The Netherlands, showed that red light reflected from the forehead could be used to measure oxygen saturation. Zijlstra initiated cuvette and catheter reflection oximetry. Instrumentation Laboratory used multiple wavelengths to measure blood carboxyhemoglobin and methemoglobin is cuvette oximeters. Shaw devised an eight-wavelength ear oximeter. Nakajima and co-workers invented the pulse oximeter, which avoids the need for calibration with only two wavelengths by responding only to the pulsatile changes in transmitted red and infrared light. Lübbers developed catheter tip and cuvette fiberoptic sensors for oxygen tension, carbon dioxide tension, and pH.

          Related collections

          Most cited references71

          • Record: found
          • Abstract: not found
          • Article: not found

          Evaluation of pulse oximetry.

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            The Oximeter, an Instrument for Measuring Continuously the Oxygen Saturation of Arterial Blood in Man

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Spectrophotometric monitoring of arterial oxygen saturation in the fingertip

                Bookmark

                Author and article information

                Journal
                Journal of Clinical Monitoring
                J Clin Monitor Comput
                Springer Science and Business Media LLC
                0748-1977
                October 1986
                October 1986
                : 2
                : 4
                : 270-288
                Article
                10.1007/BF02851177
                3537215
                630333b4-6bc6-42c8-9d13-ab3afa35ac3a
                © 1986

                http://www.springer.com/tdm

                History

                Comments

                Comment on this article