      Diagnostic Reference Ranges for Pediatric Abdominal CT

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To develop diagnostic reference ranges (DRRs) and a method for an individual practice to calculate site-specific reference doses for computed tomographic (CT) scans of the abdomen or abdomen and pelvis in children on the basis of body width (BW).

          Related collections

          Most cited references25

          • Record: found
          • Abstract: found
          • Article: not found

          CT dose reduction and dose management tools: overview of available options.

          In the past decade, the tremendous advances in computed tomography (CT) technology and applications have increased the clinical utilization of CT, creating concerns about individual and population doses of ionizing radiation. Scanner manufacturers have subsequently implemented several options to appropriately manage or reduce the radiation dose from CT. Modulation of the x-ray tube current during scanning is one effective method of managing the dose. However, the distinctions between the various tube current modulation products are not clear from the product names or descriptions. Depending on the scanner model, the tube current may be modulated according to patient attenuation or a sinusoidal-type function. The modulation may be fully preprogrammed, implemented in near-real time by using a feedback mechanism, or achieved with both preprogramming and a feedback loop. The dose modulation may occur angularly around the patient, along the long axis of the patient, or both. Finally, the system may allow use of one of several algorithms to automatically adjust the current to achieve the desired image quality. Modulation both angularly around the patient and along the z-axis is optimal, but the tube current must be appropriately adapted to patient size for diagnostic image quality to be achieved. (c) RSNA, 2006.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            American College of Radiology white paper on radiation dose in medicine.

            The benefits of diagnostic imaging are immense and have revolutionized the practice of medicine. The increased sophistication and clinical efficacy of imaging have resulted in its dramatic growth over the past quarter century. Although data derived from the atomic bomb survivors in Japan and other events suggest that the expanding use of imaging modalities using ionizing radiation may eventually result in an increased incidence of cancer in the exposed population, this problem can likely be minimized by preventing the inappropriate use of such imaging and by optimizing studies that are performed to obtain the best image quality with the lowest radiation dose. The ACR, which has been an advocate for radiation safety since its inception in 1924, convened the ACR Blue Ribbon Panel on Radiation Dose in Medicine to address these issues. This white paper details a proposed action plan for the college derived from the deliberations of that panel.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              National survey of doses from CT in the UK: 2003.

              A review of patient doses from CT examinations in the UK for 2003 has been conducted on the basis of data received from over a quarter of all UK scanners, of which 37% had multislice capability. Questionnaires were employed to collect scan details both for the standard protocols established at each scanner for 12 common types of CT examination on adults and children, and for samples of individual patients. This information was combined with published scanner-specific CT dose index (CTDI) coefficients to estimate values of the standard dose indices CTDI(w) and CTDI(vol) for each scan sequence. Knowledge of each scan length allowed assessment of the dose-length product (DLP) for each examination, from which effective doses were then estimated. When compared with a previous UK survey for 1991, wide variations were still apparent between CT centres in the doses for standard protocols. The mean UK doses for adult patients were in general lower by up to 50% than those for 1991, although doses were slightly higher for multislice (4+) (MSCT) relative to single slice (SSCT) scanners. Values of CTDI(vol) for MSCT were broadly similar to European survey data for 2001. The third quartile values of these dose distributions have been used to derive UK national reference doses for examinations on adults (separately for SSCT and MSCT) and children as initial tools for promoting patient protection. The survey has established the PREDICT (Patient Radiation Exposure and Dose in CT) database as a sustainable national resource for monitoring dose trends in CT through the ongoing collation of further survey data.
                Bookmark

                Author and article information

                Journal
                Radiology
                Radiology
                Radiological Society of North America (RSNA)
                0033-8419
                1527-1315
                July 2013
                July 2013
                : 268
                : 1
                : 208-218
                Article
                10.1148/radiol.13120730
                23513245
                652f9fd4-cafe-4a2d-bb33-0b1984f0c475
                © 2013
                History

                Comments

                Comment on this article