16
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Sustained accuracy improvement in intraocular lens power calculation with the application of quality control circle

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Accurate intraocular lens (IOL) power calculation is always a challenge in ophthalmology, and unoptimized process may lead to inaccurate refractive outcomes. Quality control circle (QCC) has shown its success in many fields as a process management tool. However, its efficacy in ophthalmology remains unclear. Here we utilized the QCC method to optimize the process and evaluate its efficacy in improving the accuracy of IOL power calculation. After the QCC application, the percentage of eyes with achieved refractive outcomes within 0.5 diopter significantly increased from 63.2% to 80.8% calculated by Haigis formula and 59.2% to 75.8% by SRK/T formula in patients with normal axial length (AL) (22 mm ≤ AL < 26 mm). Although there were no statistically significant differences in patients with long AL by the two formulas (p = 0.886 and 0.726), we achieved an accuracy of 75% with the application of the PhacoOptics software, which was significantly higher than that using the other two formulas (p < 0.001). Our findings indicated that QCC optimized and standardized the process of IOL power calculation, thus improved the accuracy of IOL power calculation in patients who underwent cataract surgery.

          Related collections

          Most cited references26

          • Record: found
          • Abstract: found
          • Article: not found

          A new initiative on precision medicine.

          President Obama has announced a research initiative that aims to accelerate progress toward a new era of precision medicine, with a near-term focus on cancers and a longer-term aim to generate knowledge applicable to the whole range of health and disease.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Comparison of 9 intraocular lens power calculation formulas.

            To evaluate the accuracy of 9 intraocular lens (IOL) calculation formulas using 2 optical biometers.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Protocols for studies of intraocular lens formula accuracy.

                Bookmark

                Author and article information

                Contributors
                lufan62@mail.eye.ac.cn
                zye@mail.eye.ac.cn
                Journal
                Sci Rep
                Sci Rep
                Scientific Reports
                Nature Publishing Group UK (London )
                2045-2322
                1 November 2017
                1 November 2017
                2017
                : 7
                : 14852
                Affiliations
                ISNI 0000 0001 0348 3990, GRID grid.268099.c, School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, ; Zhejiang, China
                Article
                14171
                10.1038/s41598-017-14171-9
                5665969
                29093540
                66081897-2f65-4ea4-af55-586b6b1df5bb
                © The Author(s) 2017

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 29 June 2017
                : 6 October 2017
                Categories
                Article
                Custom metadata
                © The Author(s) 2017

                Uncategorized
                Uncategorized

                Comments

                Comment on this article