      Amperometric flow injection analysis of glucose using immobilized glucose oxidase on nano-composite carbon nanotubes-platinum nanoparticles carbon paste electrode.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We report a novel amperometric glucose biosensor based on glucose oxidase (GOx) immobilized on a carbon nanotube (CNTs)-poly(diallyldimethyl-ammonium chloride) (PDDA)-platinum nanoparticle (PtNPs) modified carbon-paste electrode (CNTs-PDDA-PtNPs/CPE). The CNTs-PDDA-PtNPs composite materials were characterized by TEM and electrochemical techniques. Cyclic voltammetric results reveal direct electron transfer of the immobilized GOx, indicated by two quasi-reversible redox peaks at a potential of 0.37V (vs. Ag/AgCl) in phosphate buffered solution (PBS) (0.10M, pH 7). The biosensor provides good glucose oxidation activity and retention of GOx electrocatalytic activity due to CNTs-PDDA-PtNPs enhancement of the redox response. The carbon paste electrode was installed as working electrode in a flow through electrochemical cell of a flow injection (FI) system. Glucose was quantified using amperometric measurements at 0.5V vs. Ag/AgCl and PBS carrier (0.10M, pH 7.0) at a flow rate of 1.0mLmin(-1). The linear working ranges for glucose measurements were 0.1-3mM (r(2)=0.995) and 5-100mM (r(2)=0.997), with corresponding sensitivities of 0.127 and 0.060 (μAs) mM(-1), respectively. The system provides good precision of 2.8% R.S.D with a calculated detection limit (3S/N) of 15μM. The proposed method was successfully applied to determination of glucose in food and pharmaceutical samples with throughput of 200 samplesh(-1).

          Related collections

          Author and article information

          Journal
          Talanta
          Talanta
          Elsevier BV
          1873-3573
          0039-9140
          May 01 2017
          : 166
          Affiliations
          [1 ] Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand; Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Thailand. Electronic address: maliwan.a@ubu.ac.th.
          [2 ] Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani 34190, Thailand.
          [3 ] Flow Innovation-Research for Science and Technology Laboratories (FIRST Labs), Thailand; Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Mahidol University, Rama VI Road, Bangkok 10400, Thailand.
          Article
          S0039-9140(15)30526-9
          10.1016/j.talanta.2015.11.072
          28213255
          66d6ea8f-7dbd-4476-bc4a-83eb9252d1c3
          History

          Amperometry,CNTs,Carbon paste electrode,Flow injection,Glucose biosensor,PtNPs