      Posterior chamber collagen copolymer phakic intraocular lenses to correct myopia: five-year follow-up.

      Journal of Cataract and Refractive Surgery
      Adult, Collagen, Female, Follow-Up Studies, Humans, Lens Implantation, Intraocular, Male, Middle Aged, Myopia, physiopathology, surgery, Phakic Intraocular Lenses, Polymers, Posterior Eye Segment, Refraction, Ocular, physiology, Retrospective Studies, Treatment Outcome, Visual Acuity, Young Adult

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To evaluate the long-term safety and efficacy of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia. Fernández-Vega Ophthalmological Institute, Oviedo, Spain. Cohort study. Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, endothelial cell loss, and adverse events were evaluated for 5 years after implantation of the Visian Implantable Collamer Lens pIOL for moderate to high myopia. The mean spherical equivalent (188 eyes) decreased from -11.17 diopters (D) ± 3.40 (SD) preoperatively to -0.88 ± 0.72 D 5 years postoperatively. The mean change in refraction from 1 month to 5 years was -0.65 ± 0.65 D. The mean UDVA and CDVA (Snellen decimal) were 0.69 ± 0.26 and 0.83 ± 0.15, respectively. The mean safety and efficacy indices were 1.27 ± 0.33 and 0.89 ± 0.35, respectively. No eye lost more than 2 lines of visual acuity; 70% achieved 0.80 or better CDVA. Three eyes (1.6%) developed late anterior subcapsular cataract that was clinically significant in 1 case, leading to pIOL removal and phacoemulsification. Of the 3 eyes (1.6%) with a mild transient increase in intraocular pressure (up to 27 mm Hg), none required a second surgical procedure or prolonged topical medication. The total endothelial cell loss (considered cumulatively at consecutive intervals through 5 years) was 7.7%. There was a tendency toward decreased pIOL vault decrease over time. No vision-threatening complications occurred. Implantation of the collagen copolymer pIOL for moderate to high myopia was safe and effective and provided long-term predictable, stable refractive results. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

          Related collections

          Author and article information

          Comments

          Comment on this article