      Corneal assessment technologies: current status.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          There are now many devices that acquire data about the cornea: shape, power, pachymetry at any desired point of the cornea, corneal hysteresis, flap thickness (in LASIK procedures), endothelial cell count and morphology, and so forth. We review the literature on corneal assessment techniques and devices available in clinical practice. Specifically, we discuss slit lamp biomicroscopy, specular microscopy, ultrasound pachymetry, confocal microscopy, very-high-frequency digital ultrasound biomicroscopy, optical coherence tomography, Placido disk-based keratoscopy, slit-scanning elevation topography, Scheimpflug imaging, and dynamic applanation procedures-all of which can be used to assess the morphology of the cornea. In addition, we present a critical analysis of the instrumentation described and discuss the necessity of developing new technology for assessing both the morphology and the physiology of the cornea.

          Related collections

          Author and article information

          Journal
          Surv Ophthalmol
          Survey of ophthalmology
          1879-3304
          0039-6257
          : 59
          : 6
          Affiliations
          [1 ] Departamento de Física Teórica, Universidad de Valladolid, Atómica y Óptica, Valladolid, Spain; Universidad de Valladolid, Instituto Universitario de Oftalmobiología Aplicada (IOBA Eye Institute), Valladolid, Spain.
          [2 ] Departamento de Física Teórica, Universidad de Valladolid, Atómica y Óptica, Valladolid, Spain; Universidad de Valladolid, Instituto Universitario de Oftalmobiología Aplicada (IOBA Eye Institute), Valladolid, Spain. Electronic address: raul@ioba.med.uva.es.
          Article
          S0039-6257(14)00115-5
          10.1016/j.survophthal.2014.05.001
          25223496
          68fb63bf-5b9d-40ea-90f2-473858270f34
          Copyright © 2014 Elsevier Inc. All rights reserved.
          History

          Orbscan topography,confocal microscopy,corneal morphology assessment,dynamic applanation procedures,optical coherence tomography (OCT),placido disk,scheimpflug imaging,specular microscopy,ultrasound pachymetry,very high-frequency (VHF) digital ultrasound biomicroscopy

          Comments