      Diagnostic power of the vaginal washing-fluid prolactin assay as an alternative method for the diagnosis of premature rupture of membranes.

      The Journal of Maternal-Fetal & Neonatal Medicine
      Adult, Amniotic Fluid, chemistry, Case-Control Studies, Female, Fetal Membranes, Premature Rupture, diagnosis, Humans, Predictive Value of Tests, Pregnancy, Pregnancy Trimesters, Prolactin, analysis, ROC Curve, Reference Values, Reproducibility of Results, Sensitivity and Specificity, Vagina

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The purpose of this study was to determine the reliability of the vaginal washing-fluid prolactin assay for the diagnosis of premature rupture of membranes (PROM) and to determine a diagnostic cut-off value. Seventy pregnant women between 11 and 40 weeks of gestation who were admitted with vaginal fluid leakage were included in the study group, and were then further subdivided into two subgroups according to amniotic fluid pooling and nitrazine paper test results. Group 1 was the 'confirmed PROM group', positive for both pooling and nitrazine (38 patients). Group 2 was the 'suspected but unconfirmed PROM group' which had possible pooling and/or nitrazine (32 patients). Seventy pregnant women between 11 and 40 weeks of gestation without any complaint and complication were included in the control group (group 3). All patients underwent vaginal washing-fluid sampling and prolactin level determination. For the statistical analysis one-way analysis of variance, Tukey multiple comparison test, chi2 test and receiver operating characteristic (ROC) curve analysis were used. Geometric mean values of vaginal washing-fluid prolactin levels were 616.59 microIU/ml for group 1, 23.98 microIU/ml for group 2 and 10 microIU/ml for group 3 (p < 0.0001). The optimal diagnostic cut-off value was found to be 30 microIU/ml with 95% sensitivity, 78% specificity, 84% positive predictive value, 93% negative predictive value, 87% accuracy and 11.30 relative risk. We recommend vaginal washing-fluid prolactin level determination as an alternative diagnostic method for PROM.

          Related collections

          Author and article information

          Comments

          Comment on this article