40
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      The feasibility of automated online flow cytometry for in-situ monitoring of microbial dynamics in aquatic ecosystems

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Fluorescent staining coupled with flow cytometry (FCM) is often used for the monitoring, quantification and characterization of bacteria in engineered and environmental aquatic ecosystems including seawater, freshwater, drinking water, wastewater, and industrial bioreactors. However, infrequent grab sampling hampers accurate characterization and subsequent understanding of microbial dynamics in all of these ecosystems. A logic technological progression is high throughput and full automation of the sampling, staining, measurement, and data analysis steps. Here we assess the feasibility and applicability of automated FCM by means of actual data sets produced with prototype instrumentation. As proof-of-concept we demonstrate examples of microbial dynamics in (i) flowing tap water from a municipal drinking water supply network and (ii) river water from a small creek subject to two rainfall events. In both cases, automated measurements were done at 15-min intervals during 12–14 consecutive days, yielding more than 1000 individual data points for each ecosystem. The extensive data sets derived from the automated measurements allowed for the establishment of baseline data for each ecosystem, as well as for the recognition of daily variations and specific events that would most likely be missed (or miss-characterized) by infrequent sampling. In addition, the online FCM data from the river water was combined and correlated with online measurements of abiotic parameters, showing considerable potential for a better understanding of cause-and-effect relationships in aquatic ecosystems. Although several challenges remain, the successful operation of an automated online FCM system and the basic interpretation of the resulting data sets represent a breakthrough toward the eventual establishment of fully automated online microbiological monitoring technologies.

          Related collections

          Most cited references50

          • Record: found
          • Abstract: not found
          • Book: not found

          Numerical Ecology with R

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Flow-cytometric total bacterial cell counts as a descriptive microbiological parameter for drinking water treatment processes.

            There are significantly more microbial cells in drinking water than what can be cultured on synthetic growth media. Nonetheless, cultivation-based heterotrophic plate counts (HPCs) are used worldwide as a general microbial quality parameter in drinking water treatment and distribution. Total bacterial cell concentrations are normally not considered during drinking water treatment as a design, operative or legislative parameters. This is mainly because easy and rapid methods for quantification of total bacterial cell concentrations have, up to now, not been available. As a consequence, the existing lack of data does not allow demonstrating the practical value of this parameter. In this study, we have used fluorescence staining of microbial cells with the nucleic acid stain SYBR((R)) Green I together with quantitative flow cytometry (FCM) to analyse total cell concentrations in water samples from a drinking water pilot plant. The plant treats surface water (Lake Zürich) through sequential ozonation, granular active carbon (GAC) filtration and membrane ultrafiltration (UF). The data were compared with adenosine tri-phosphate (ATP) measurements and conventional HPCs performed on the same water samples. We demonstrated that the impact of all three major treatment steps on the microbiology in the system could accurately be described with total cell counting: (1) ozonation caused chemical destruction of the bacterial cells; (2) GAC filtration facilitated significant regrowth of the microbial community; and (3) membrane UF physically removed the bacterial cells from the water. FCM typically detected 1-2 log units more than HPC, while ATP measurements were prone to interference from extracellular ATP released during the ozonation step in the treatment train. We have shown that total cell concentration measured with FCM is a rapid, easy, sensitive and importantly, a descriptive parameter of several widely applied drinking water treatment processes.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Monitoring microbiological changes in drinking water systems using a fast and reproducible flow cytometric method.

              Flow cytometry (FCM) is a rapid, cultivation-independent tool to assess and evaluate bacteriological quality and biological stability of water. Here we demonstrate that a stringent, reproducible staining protocol combined with fixed FCM operational and gating settings is essential for reliable quantification of bacteria and detection of changes in aquatic bacterial communities. Triplicate measurements of diverse water samples with this protocol typically showed relative standard deviation values and 95% confidence interval values below 2.5% on all the main FCM parameters. We propose a straightforward and instrument-independent method for the characterization of water samples based on the combination of bacterial cell concentration and fluorescence distribution. Analysis of the fluorescence distribution (or so-called fluorescence fingerprint) was accomplished firstly through a direct comparison of the raw FCM data and subsequently simplified by quantifying the percentage of large and brightly fluorescent high nucleic acid (HNA) content bacteria in each sample. Our approach enables fast differentiation of dissimilar bacterial communities (less than 15 min from sampling to final result), and allows accurate detection of even small changes in aquatic environments (detection above 3% change). Demonstrative studies on (a) indigenous bacterial growth in water, (b) contamination of drinking water with wastewater, (c) household drinking water stagnation and (d) mixing of two drinking water types, univocally showed that this FCM approach enables detection and quantification of relevant bacterial water quality changes with high sensitivity. This approach has the potential to be used as a new tool for application in the drinking water field, e.g. for rapid screening of the microbial water quality and stability during water treatment and distribution in networks and premise plumbing. Copyright © 2013 Elsevier Ltd. All rights reserved.
                Bookmark

                Author and article information

                Contributors
                Journal
                Front Microbiol
                Front Microbiol
                Front. Microbiol.
                Frontiers in Microbiology
                Frontiers Media S.A.
                1664-302X
                09 April 2014
                02 June 2014
                2014
                : 5
                : 265
                Affiliations
                [1] 1Department of Environmental Microbiology, Eawag – Swiss Federal Institute for Aquatic Science and Technology Dübendorf, Switzerland
                [2] 2Department of Environmental Systems Science, Institute of Biogeochemistry and Pollutant Dynamics, ETH Zürich Zürich, Switzerland
                [3] 3Institute of Environmental Engineering, Chair of Process Engineering in Urban Water Management, ETH Zürich Zürich, Switzerland
                Author notes

                Edited by: Susann Müller, Helmholtz Centre for Environmental Research, Germany

                Reviewed by: Lee-Ann H. Allen, University of Iowa, USA; Andreas Nocker, Cranfield University, UK; Andreas H. Farnleitner, Vienna University of Technology, Austria; Susanne Günther, Helmholtz Centre for Environmental Research, Germany

                *Correspondence: Frederik Hammes, Drinking Water Microbiology Group, Department of Environmental Microbiology, Eawag – Swiss Federal Institute for Aquatic Science and Technology, Überlandstrasse 133, 8600 Dübendorf, Switzerland e-mail: frederik.hammes@ 123456eawag.ch

                This article was submitted to Systems Microbiology, a section of the journal Frontiers in Microbiology.

                Article
                10.3389/fmicb.2014.00265
                4040452
                24917858
                6a8042f7-e2ec-4651-a111-02cbc4c26ed4
                Copyright © 2014 Besmer, Weissbrodt, Kratochvil, Sigrist, Weyland and Hammes.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) or licensor are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

                History
                : 20 February 2014
                : 15 May 2014
                Page count
                Figures: 6, Tables: 1, Equations: 0, References: 50, Pages: 12, Words: 7739
                Categories
                Microbiology
                Original Research Article

                Microbiology & Virology
                flow cytometry (fcm),bacteria,drinking water,monitoring,sensors,automation,online,staining

                Comments