38
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Risk factors for aseptic loosening of Müller-type straight stems : A registry-based analysis of 828 consecutive cases with a minimum follow-up of 16 years

      research-article
      1 , , 1 , 2 , 1
      Acta Orthopaedica
      Informa Healthcare

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background and purpose

          Even small differences in design variables for the femoral stem may influence the outcome of a hip arthroplasty. We performed a risk factor analysis for aseptic loosening of 4 different versions of cemented Müller-type straight stems with special emphasis on design modifications (2 shapes, MSS or SL, and 2 materials, CoNiCrMo (Co) or Ti-6Al-7Nb (Ti)).

          Methods

          We investigated 828 total hip replacements, which were followed prospectively in our in-house register. All stems were operated in the same setup, using Sulfix-6 bone cement and a second-generation cementing technique. Demographic and design-specific risk factors were analyzed using an adjusted Cox regression model.

          Results

          The 4 versions showed marked differences in 15-year stem survival with aseptic loosening as the endpoint: 94% (95% CI: 89–99) for MSS Co, 83% (CI: 75–91) for SL Co, 81% (CI: 76–87) for MSS Ti and 63% (CI: 56–71) for SL Ti. Cox regression analysis showed a relative risk (RR) for aseptic loosening of 3 (CI: 2–5) for stems made of Ti and of 2 (CI: 1–2) for the SL design. The RR for aseptic stem loosening increased to 8 (CI: 4–15) when comparing the most and the least successful designs (MSS Co and SL Ti).

          Interpretation

          Cemented Müller-type straight stems should be MSS-shaped and made of a material with high flexural strength (e.g. cobalt-chrome). The surface finish should be polished (Ra < 0.4 µm). These technical aspects combined with modern cementing techniques would improve the survival of Müller-type straight stems. This may be true for all types of cemented stems.

          Related collections

          Most cited references37

          • Record: found
          • Abstract: found
          • Article: not found

          The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties.

          In 1985, the Norwegian Orthopaedic Association decided to establish a national hip register, and the Norwegian Arthroplasty Register was started in 1987. In January 1994, it was extended to include all artificial joints. The main purpose of the register is to detect inferior results of implants as early as possible. All hospitals participate, and the orthopedic surgeons are supposed to report all primary operations and all revisions. Using the patient's unique national social security number, the revision can be linked to the primary operation, and survival analyses of the implants are done. In general, the survival analyses are performed with the Kaplan-Meier method or using Cox multiple regression analysis with adjustment for possible confounding factors such as age, gender, and diagnosis. Survival probabilities can be calculated for each of the prosthetic components. The end-point in the analyses is revision surgery, and we can assess the rate of revision due to specific causes like aseptic loosening, infection, or dislocation. Not only survival, but also pain, function, and satisfaction have been registered for subgroups of patients. We receive reports about more than 95% of the prosthesis operations. The register has detected inferior implants 3 years after their introduction, and several uncemented prostheses were abandoned during the early 1990s due to our documentation of poor performance. Further, our results also contributed to withdrawal of the Boneloc cement. The register has published papers on economy, prophylactic use of antibiotics, patients' satisfaction and function, mortality, and results for different hospital categories. In the analyses presented here, we have compared the results of primary cemented and uncemented hip prostheses in patients less than 60 years of age, with 0-11 years' follow-up. The uncemented circumferentially porous- or hydroxyapatite (HA)-coated femoral stems had better survival rates than the cemented ones. In young patients, we found that cemented cups had better survival than uncemented porous-coated cups, mainly because of higher rates of revision from wear and osteolysis among the latter. The uncemented HA-coated cups with more than 6 years of follow-up had an increased revision rate, compared to cemented cups due to aseptic loosening as well as wear and osteolysis. We now present new findings about the six commonest cemented acetabular and femoral components. Generally, the results were good, with a prosthesis survival of 95% or better at 10 years, and the differences among the prosthesis brands were small. Since the practice of using undocumented implants has not changed, the register will continue to survey these implants. We plan to assess the mid- and long-term results of implants that have so far had good short-term results.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty.

            At a minimum of one year after operation, we studied 64 patients with 86 total hip arthroplasties (THA) by standard anteroposterior hip and pelvic radiographs and measurement of range of motion and of isometric abduction strength. The femoral offset correlated positively with the range of abduction (p = 0.046). Abduction strength correlated positively with both femoral offset (p = 0.0001) and the length of the abductor lever arm (p = 0.005). Using multiple regression, abduction strength correlated with height (p = 0.017), gender (p = 0.0005), range of flexion (p = 0.047) and the abductor lever arm (p = 0.060). Our findings suggest that greater femoral offset after THA allows both an increased range of abduction and greater abductor strength.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases.

              The Swedish Hip Register has defined the epidemiology of total hip replacement in Sweden. Most hip implants are fully cemented. Serious complications and rates of revision have declined significantly despite an increasing number of patients at risk. During the past 5 years, only 8-9% of hip replacements are revisions. Aseptic loosening with or without osteolysis is the major problem and constitutes 71% of the revisions, but the incidence had decreased three times during the past 15 years to less than 3% at 10 years. The effectiveness of the surgical technique is the most important factor for reducing the risk of revision because of aseptic loosening, but choice of implant is also important. In practice, total hip replacement in Sweden has improved, as judged by information from this Register about individualized patient risks, implant safety, and the greater efficacy of surgical and cementing techniques.
                Bookmark

                Author and article information

                Journal
                Acta Orthop
                Acta Orthop
                ORT
                Acta Orthopaedica
                Informa Healthcare
                1745-3674
                1745-3682
                August 2013
                2 September 2013
                : 84
                : 4
                : 353-359
                Affiliations
                1Clinic for Orthopedic and Trauma Surgery , Kantonsspital Baselland Liestal
                2RMS Foundation , Bettlach, Switzerland.
                Author notes
                Article
                ORT_A_810517_O
                10.3109/17453674.2013.810517
                3768033
                23799347
                6c35a404-6935-4f6a-8aad-db6d7f2e885f
                Copyright: © Nordic Orthopaedic Federation

                This is an open-access article distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited.

                History
                : 12 July 2012
                : 11 April 2013
                Categories
                Hip

                Orthopedics
                Orthopedics

                Comments

                Comment on this article