      Simulation of transcatheter aortic valve implantation: a patient-specific finite element approach.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Until recently, heart valve failure has been treated adopting open-heart surgical techniques and cardiopulmonary bypass. However, over the last decade, minimally invasive procedures have been developed to avoid high risks associated with conventional open-chest valve replacement techniques. Such a recent and innovative procedure represents an optimal field for conducting investigations through virtual computer-based simulations: in fact, nowadays, computational engineering is widely used to unravel many problems in the biomedical field of cardiovascular mechanics and specifically, minimally invasive procedures. In this study, we investigate a balloon-expandable valve and we propose a novel simulation strategy to reproduce its implantation using computational tools. Focusing on the Edwards SAPIEN valve in particular, we simulate both stent crimping and deployment through balloon inflation. The developed procedure enabled us to obtain the entire prosthetic device virtually implanted in a patient-specific aortic root created by processing medical images; hence, it allows evaluation of postoperative prosthesis performance depending on different factors (e.g. device size and prosthesis placement site). Notably, prosthesis positioning in two different cases (distal and proximal) has been examined in terms of coaptation area, average stress on valve leaflets as well as impact on the aortic root wall. The coaptation area is significantly affected by the positioning strategy (- 24%, moving from the proximal to distal) as well as the stress distribution on both the leaflets (+13.5%, from proximal to distal) and the aortic wall (- 22%, from proximal to distal). No remarkable variations of the stress state on the stent struts have been obtained in the two investigated cases.

          Related collections

          Author and article information

          Journal
          Comput Methods Biomech Biomed Engin
          Computer methods in biomechanics and biomedical engineering
          Informa UK Limited
          1476-8259
          1025-5842
          2014
          : 17
          : 12
          Affiliations
          [1 ] a Dipartimento di Ingegneria Civile e Architettura (DICAr) , Università degli Studi di Pavia , Via Ferrata 1, 27100, Pavia , Italy.
          Article
          10.1080/10255842.2012.746676
          23402555
          6cd40440-74b2-4950-9bdb-1e4aeb45d9a2
          History

          finite element analysis,patient-specific modelling,transcatheter aortic valve

          Comments

          Comment on this article