          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          We aimed to evaluate a modified endotracheal tube containing upper and lower balloons for anesthetic administration among patients undergoing laparoscopic cholecystectomy.

          Methods

          Ninety patients scheduled to undergo laparoscopic cholecystectomy were randomly allocated to 3 equal groups: group A (conventional tracheal intubation without endotracheal anesthesia); B (conventional tracheal intubation with endotracheal anesthesia); and C (tracheal intubation using a modified catheter under study). Blood pressure, heart rate, angiotensin II level, blood glucose level, airway pressure before anesthesia (T1) were measured immediately after intubation (T2), 5 min after intubation (T3), and immediately after extubation (T4). The post-extubation pain experienced was evaluated using the Wong-Baker Face Pain scale. Adverse reactions within 30 min after extubation were recorded.

          Results

          Systolic blood pressure, diastolic blood pressure, angiotensin II, and blood sugar level in group C at T2, T3 and T4, and heart rate at T2 and T4 were significantly lower than those in group A ( P < 0.05); systolic blood pressure and blood sugar at T4, and angiotensin II levels at T2, T3, and T4 were significantly lower than those in group B ( P < 0.05). Patients in group C reported the lowest post-extubation pain ( P < 0.05 vs. Group A), and the lowest incidence of adverse events such as nausea, vomiting, and sore throat than that in groups A and B ( P < 0.05).

          Conclusion

          The modified endotracheal anesthesia tube under study is effective in reducing cardiovascular and tracheal stress response, and increasing patient comfort, without inducing an increase in airway resistance.

          Trial registration

          The clinical trial was retrospectively registered at the Chinese Clinical Trial Registry with the Registration Number ChiCTR1900020832 at January 20th 2019.

          Related collections

          Most cited references24

          • Record: found
          • Abstract: not found
          • Article: not found
          Is Open Access

          Comparative evaluation of passive, active, and passive-active distraction techniques on pain perception during local anesthesia administration in children

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Benzydamine hydrochloride on postoperative sore throat: a meta-analysis of randomized controlled trials.

            Sore throat is a common postoperative complaint. The etiology of postoperative sore throat (POST) is considered the result of damage to airway mucosa after insertion of a laryngeal mask airway device or endotracheal tube. This paper proposes benzydamine hydrochloride (BH), a topical nonsteroidal anti-inflammatory drug (NSAID) with additional analgesic and local anesthetic properties, for POST prevention.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Dose-related attenuation of cardiovascular responses to tracheal intubation by intravenous remifentanil bolus in severe pre-eclamptic patients undergoing Caesarean delivery.

              The optimal dose of remifentanil to attenuate the cardiovascular responses to tracheal intubation in pre-eclamptic patients undergoing Caesarean delivery under general anaesthesia has not been established. We compared the effects of two low doses of remifentanil on the cardiovascular responses to tracheal intubation and neonatal outcomes. Forty-eight women with severe pre-eclampsia were randomly assigned to receive either remifentanil 0.5 µg kg⁻¹ (R0.5 group, n=24) or 1 µg kg⁻¹ (R1.0 group, n=24) over 30 s before induction of anaesthesia using thiopental 5 mg kg⁻¹ and succinylcholine 1.5 mg kg⁻¹. Systolic arterial pressure (SAP), heart rate (HR), and plasma catecholamine concentrations were measured. Neonatal effects were assessed using Apgar scores and umbilical cord blood gas analysis. SAP was decreased by induction of anaesthesia and increased by tracheal intubation in both groups. The peak SAP after intubation was greater in the R0.5 group than in the R1.0 group, whereas it did not exceed baseline values in either group. HR increased significantly above baseline in both groups with no significant differences between the groups. Three subjects in the R1.0 group received ephedrine due to hypotension (SAP < 90 mm Hg). Norepinephrine concentrations remained unaltered after intubation and increased significantly at delivery with no significant differences between the groups. Neonatal Apgar scores and umbilical arterial and venous pH and blood gas values were comparable between the groups. Both doses of remifentanil effectively attenuated haemodynamic responses to tracheal intubation with transient neonatal respiratory depression in pre-eclamptic patients undergoing Caesarean delivery under general anaesthesia. The 1.0 µg kg⁻¹ dose was associated with hypotension in three of 24 subjects.
                Bookmark

                Author and article information

                Contributors
                36856665@qq.com
                mz19700720@163.com
                15916547823@163.com
                hongfengfeixue@21.com
                43906672@qq.com
                693757325@qq.com
                Journal
                BMC Anesthesiol
                BMC Anesthesiol
                BMC Anesthesiology
                BioMed Central (London )
                1471-2253
                15 November 2019
                15 November 2019
                2019
                : 19
                : 211
                Affiliations
                [1 ]First Department of Anesthesiology, People’s Hospital of Meizhou City, Meizhou, Guangdong Province China
                [2 ]GRID grid.443485.a, Department of Laboratory Medicine, , Jiaying University of Meizhou City, ; Meizhou, Guangdong Province China
                Author information
                http://orcid.org/0000-0002-1666-4595
                Article
                883
                10.1186/s12871-019-0883-7
                6857317
                31729976
                6d3b6920-cb9c-4c5f-ac7a-50433662cede
                © The Author(s). 2019

                Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License ( http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

                History
                : 19 September 2019
                : 30 October 2019
                Categories
                Research Article
                Custom metadata
                © The Author(s) 2019

                Anesthesiology & Pain management
                induction of anesthesia,tracheal intubation,tracheal catheter with dual administration channels,cardiovascular response,comfort

                Comments

                Comment on this article