      On the use of the "look-locker correction" for calculating T1 values from MOLLI

      abstract
      1 ,
      Journal of Cardiovascular Magnetic Resonance
      BioMed Central
      17th Annual SCMR Scientific Sessions
      16-19 January 2014

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background MOLLI [1] uses interleaved Look-Locker (LL) blocks for cardiac T1 mapping. Data is fit to the equation A-Bexp(-TI/T1*) to yield an "apparent" T1 (T1*), which is dependent on both the true T1 and imaging parameters. To estimate true T1, a "LL correction" T1est=(B/A-1)T1* [Eq. 1] has been proposed [1,2]. Although this correction can provide reasonable estimates of true T1, we are not aware of a rigorous justification for its use. The purpose of this work was to investigate the applicability of this correction for MOLLI. Methods The LL correction (Eq. 1) is based on the following conditions [2]: 1) continuous imaging; 2) spoiled-gradient-echo (SPGR) readout; 3) TR << T1; and 4) negligible initial delays after inversion (TI0) and between images (e.g., IR cine). MOLLI uses a bSSFP readout which does not satisfy conditions 1 and 2. If the entire bSSFP readout were conceptually replaced with a single excitation pulse [3], MOLLI would approximate a LL-SPGR acquisition. However, this is not a theoretically valid simplification, and both T1* and T1est will be underestimated (Figure 1). This simplification also implies TR = TRR (RR interval). For cardiac imaging (T1≈1200 ms, TRR ≈1000 ms), this violates condition 3 and can also be shown to underestimate T1est. Further, MOLLI utilizes non-zero TI0s which violate condition 4. As TI0 increases, the curve-fitting algorithm appropriately produces an increasingly negative y-intercept A-B (thus larger B/A) and a longer T1* (because of the added true T1 relaxation during TI0). Eq. 1 thus causes T1est to illogically become a function of TI0 which leads to overestimation at longer TI0. Finally, MOLLI involves the interleaving of three LL blocks, each with an incremented TI0. The resulting composite curve consists of two distinct regions of magnetization recovery (Figure 2). This has the counterintuitive effect of causing the composite T1* to be larger than the individual T1*s. Figure 1 Simulated recovery curves for i) MOLLI (single LL block) (black) and ii) simplified MOLLI model where the bSSFP readout is replaced by a single excitation (blue). Curves begin at different levels of transverse magnetization due to 8 dummy TRs used for MOLLI. Because the simplified model ignores the effects of multiple excitations, the recovery is dominated by free T1 relaxation. Thus, the T1* of the actual MOLLI data will always be less than that of the simplified model. T1est will be similarly underestimated. Simulated parameters: T1/T2 = 1200/40 ms (normal myocardium), TR = 3.0 ms, 35° flip angle; 60 bpm heart rate Figure 2 Simulated magnetization recovery for MOLLI consisting of three interleaved LL blocks (T1 = 1200 ms). The composite MOLLI curve (black line) is made up of two distinct recovery regions: 1) Data points from individual LL blocks (red, green, and blue) which follow their respective (i.e., different) T1* and 2) data points in each hashed box which are essentially acquired in a single-point fashion and follow true T1 relaxation. The T1 contribution causes the composite T1* to be greater than the T1*s of the individual LL blocks. This counterintuitive result is in contrast to the mathematical expectation that a composite exponential curve should have a time constant intermediate to those of the component exponentials. Results The MOLLI acquisition does not satisfy the requirements on which the LL correction is based. For a single LL block, each violation produces an error in T1est. When LL blocks are combined, however, the overestimation caused by interleaving LL blocks obtained with non-zero TI0 partially offsets the underestimation from the misapplied simplification and correction. Under certain conditions, this yields a reasonable estimate of T1, with the error being strongly dependent on the range of TI0. In practice, TI0 is typically too short to completely offset the effects of the LL correction, resulting in the observed systematic underestimation of T1. Conclusions The use of multiple LL blocks in MOLLI was intended to improve accuracy by increasing the sampling of the relaxation curve. Instead, it can be shown that this distinguishing feature of MOLLI has the unexpected effect of essentially averaging out errors introduced by the LL correction. However, T1 estimates derived from MOLLI using the LL correction cannot be consistently accurate because of the violated conditions of its use. Funding None.

          Related collections

          Author and article information

          Conference
          J Cardiovasc Magn Reson
          J Cardiovasc Magn Reson
          Journal of Cardiovascular Magnetic Resonance
          BioMed Central
          1097-6647
          1532-429X
          2014
          16 January 2014
          : 16
          : Suppl 1
          : P55
          Affiliations
          [1 ]GE Healthcare, Bethesda, Maryland, USA
          Article
          1532-429X-16-S1-P55
          10.1186/1532-429X-16-S1-P55
          4044058
          6df5c032-514e-4d25-8827-f5e7526ff36e
          Copyright © 2014 Slavin; licensee BioMed Central Ltd.

          This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

          17th Annual SCMR Scientific Sessions
          New Orleans, LA, USA
          16-19 January 2014
          History
          Categories
          Poster Presentation

          Cardiovascular Medicine
          Cardiovascular Medicine

          Comments

          Comment on this article