      Lightwand-Guided Insertion of Flexible Reinforced Laryngeal Mask Airway: Comparison with Standard Digital Manipulation Insertion

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          The flexibility of the long flexometallic tube makes insertion of the flexible reinforced laryngeal mask airway (f-LMA) difficult. We compared the usefulness of rigid lightwand-guided f-LMA insertion with standard digital manipulation.

          Material/Methods

          Fifty-four patients (aged 19–70 years) were randomly divided into a control group (digital manipulation technique) or the lightwand group (lightwand-guided insertion technique). The insertion profiles, oropharyngeal leak pressure (OLP), peak inspiratory pressure (PIP), expiratory tidal volume, and ventilatory score were measured in patients with neutral, extension, rotation, flexion, and re-neutral head-neck positions in turn.

          Results

          The success rate and ease of insertion did not differ between groups, but the insertion time was longer in the lightwand group. The fiberoptic laryngeal view was significantly better in the lightwand group than in the control group. However, the OLP, PIP, expiratory tidal volume, and ventilatory scores were not significantly different between groups according to head-neck positions. The extension posture was associated with a significant negative effect on ventilation, but ventilation returned to initial levels with the other postures.

          Conclusions

          Lightwand-guided f-LMA insertion showed a better fiberoptic laryngeal view than standard digital manipulation, but no improvement in the ventilatory state was observed due to position. Therefore, lightwand-guided insertion could facilitate correct placement of the f-LMA, but it has limited clinical usefulness.

          Related collections

          Most cited references34

          • Record: found
          • Abstract: found
          • Article: not found

          A clinical sign to predict difficult tracheal intubation: a prospective study.

          It has been suggested that the size of the base of the tongue is an important factor determining the degree of difficulty of direct laryngoscopy. A relatively simple grading system which involves preoperative ability to visualize the faucial pillars, soft palate and base of uvula was designed as a means of predicting the degree of difficulty in laryngeal exposure. The system was evaluated in 210 patients. The degree of difficulty in visualizing these three structures was an accurate predictor of difficulty with direct laryngoscopy (p less than 0.001).
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Predicting difficult intubation.

            The amount of larynx seen at intubation was assessed in 633 adult patients undergoing routine surgery. Various measurements of the head and neck were made in an attempt to discover which features were associated with difficulty with laryngoscopy (defined as the inability to see even the arytenoids). In addition 38 patients, reported by colleagues because they had been "difficult to intubate", were measured. Five useful risk factors, measured at three levels of severity, were identified. A simple predictive rule was developed and tested on a prospective set of 778 patients, in 1.5% of whom laryngoscopy was found to be difficult. Depending on the threshold chosen, the rule allowed the detection of, for example, 75% of the "difficult" laryngoscopies at a cost of falsely identifying 12% of the "not difficult" patients.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Comparison of four methods for assessing airway sealing pressure with the laryngeal mask airway in adult patients.

              We have compared four tests for assessing airway sealing pressure with the laryngeal mask airway (LMA) to test the hypothesis that airway sealing pressure and inter-observer reliability differ between tests. We studied 80 paralysed, anaesthetized adult patients. Four different airway sealing pressure tests were performed in random order on each patient by two observers blinded to each other's measurements: test 1 involved detection of an audible noise; test 2 was detection of end-tidal carbon dioxide in the oral cavity; test 3 was observation of the aneroid manometer dial as the pressure increased to note the airway pressure at which the dial reached stability; and test 4 was detection of an audible noise by neck auscultation. Mean airway sealing pressure ranged from 19.5 to 21.3 cm H2O and intra-class correlation coefficient was 0.95-0.99. Inter-observer reliability of all tests was classed as excellent. The manometric stability test had a higher mean airway sealing pressure (P < 0.0001) and better inter-observer reliability (P < 0.0001) compared with the three other tests. We conclude that for clinical purposes all four tests are excellent, but that the manometric stability test may be more appropriate for researchers comparing airway sealing pressures.
                Bookmark

                Author and article information

                Journal
                Med Sci Monit
                Med Sci Monit
                Medical Science Monitor
                Medical Science Monitor : International Medical Journal of Experimental and Clinical Research
                International Scientific Literature, Inc.
                1234-1010
                1643-3750
                2021
                11 January 2021
                12 November 2020
                : 27
                : e928538-1-e928538-8
                Affiliations
                Department of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, Gyeonggi, South Korea
                Author notes
                Corresponding Author: Ji Young Yoo, e-mail: springbear@ 123456nate.com
                [A]

                Study Design

                [B]

                Data Collection

                [C]

                Statistical Analysis

                [D]

                Data Interpretation

                [E]

                Manuscript Preparation

                [F]

                Literature Search

                [G]

                Funds Collection

                [*]

                Dae Hee Kim, Yun Jeong Chae contributed equally to this work

                Article
                928538
                10.12659/MSM.928538
                7812698
                33428608
                71c0d6e1-29b4-4cba-aa73-8d0c77fe20c5
                © Med Sci Monit, 2021

                This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International ( CC BY-NC-ND 4.0)

                History
                : 14 September 2020
                : 27 October 2020
                Categories
                Clinical Research

                airway management,laryngeal masks,ventilation
                airway management, laryngeal masks, ventilation

                Comments

                Comment on this article