15
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Left superior vena cava persistence in patients undergoing pacemaker or cardioverter-defibrillator implantation: a 10-year experience.

      Chest
      Defibrillators, Implantable, Female, Heart Block, therapy, Humans, Male, Middle Aged, Pacemaker, Artificial, Prospective Studies, Sick Sinus Syndrome, Tachycardia, Ventricular, Vena Cava, Superior, abnormalities

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The persistence of a left superior vena cava (LSVC) has been observed in 0.3% of the general population as established by autopsy. In the adult population, it is an important anatomic finding if a left superior approach to the heart is considered. The aim of the study was to evaluate the prevalence of a LSVC in patients undergoing pacemaker (PM) and cardioverter-defibrillator (CD) implantation. We observed the prevalence of LSVC during a 10-year period; each patient undergoing PM or transvenous CD implantation received a left cephalic/left subclavian venous approach to the heart. With this technique, LSVC persistence is easily diagnosed during lead placement. A total of 1,139 patients consecutively underwent PM implantation during 10 years: 4 patients had persistent LSCV (0.34%). Among 115 patients undergoing CD implantation, 2 patients with LSVC (1.7%) were observed. Overall LSVC persistence was found in 6 of 1,254 patients (0.47%). Two patients, one of whom had no right superior vena cava (RSVC), received a left-sided PM, whereas two other patients received right-sided devices. Both CD patients received a left-sided active-can device: the first patient with a right-sided lead tunneled to the left pectoral pocket, as a result of poor catheter handling through the LSVC and coronary sinus, and the second patient with a screw-in lead from LSVC. Long-term follow-up of these patients (average +/- SD, 41 +/- 26 months) revealed absence of lead dislodgment and appropriate device function regardless of lead implantation site. Persistence of LSVC in adults undergoing PM/CD implantation is similar to that of the general population (0.47% in our study). The left-sided implant can be achieved by stylet shaping and by use of active fixation leads in most patients, with a reliable outcome at short term in addition to appropriate device performance at follow-up. Assessment of the RSVC is advisable when planning a right-sided implantation, since a minority of patients lacks this vessel.

          Related collections

          Author and article information

          Comments

          Comment on this article