      The MYTHEN detector for X-ray powder diffraction experiments at the Swiss Light Source

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A report on the characterization, calibration and performances of the MYTHEN photon-counting silicon microstrip detector at the powder diffraction station at the Swiss Light Source is given.

          Abstract

          The MYTHEN single-photon-counting silicon microstrip detector has been developed at the Swiss Light Source for time-resolved powder diffraction experiments. An upgraded version of the detector has been installed at the SLS powder diffraction station allowing the acquisition of diffraction patterns over 120° in 2θ in fractions of seconds. Thanks to the outstanding performance of the detector and to the calibration procedures developed, the quality of the data obtained is now comparable with that of traditional high-resolution point detectors in terms of FWHM resolution and peak profile shape, with the additional advantage of fast and simultaneous acquisition of the full diffraction pattern. MYTHEN is therefore optimal for time-resolved or dose-critical measurements. The characteristics of the MYTHEN detector together with the calibration procedures implemented for the optimization of the data are described in detail. The refinements of two known standard powders are discussed together with a remarkable application of MYTHEN to organic compounds in relation to the problem of radiation damage.

          Related collections

          Most cited references1

          • Record: found
          • Abstract: not found
          • Article: not found

          In situ observation of rapid reactions in nanoscale Ni–Al multilayer foils using synchrotron radiation

            Bookmark

            Author and article information

            Journal
            J Synchrotron Radiat
            J. Synchrotron Rad.
            Journal of Synchrotron Radiation
            International Union of Crystallography
            0909-0495
            1600-5775
            01 September 2010
            22 July 2010
            22 July 2010
            : 17
            : Pt 5 ( publisher-idID: s100500 )
            : 653-668
            Affiliations
            [a ]Paul Scherrer Institut, CH-5232 Villigen, Switzerland
            Author notes
            Correspondence e-mail: anna.bergamaschi@ 123456psi.ch
            Article
            gf5028 JSYRES S0909049510026051
            10.1107/S0909049510026051
            2924792
            20724787
            72640f9d-f727-47fd-bf96-95574b79a2eb
            © Anna Bergamaschi et al. 2010

            This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.

            History
            : 11 May 2010
            : 01 July 2010
            Categories
            Research Papers

            Radiology & Imaging
            powder diffraction,detectors
            Radiology & Imaging
            powder diffraction, detectors

            Comments

            Comment on this article