      A simple yet novel solution to prevent stent stripping in Guidezilla use

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Introduction Guide extension catheters are particularly useful when performing percutaneous coronary intervention (PCI) in coronary arteries with difficult anatomy, for example, coronary ostial occlusions that cannot be easily accessed or cannulated with routinely used guide catheters, highly calcified and tortuous coronary arteries, and chronic total occlusions (1-5). Guide extension catheters facilitate complex procedures by enabling deep coronary artery cannulation, thereby increasing back-up support and allowing coaxial alignment (2, 5). The risk of stent stripping while advancing the stent into support guide extension catheter is particularly associated with the Guidezilla guide extension catheter system (Boston Scientific) (6). We present this case as an example of a simple but novel solution for preventing this complication. Case Report A 62-year-old male patient was admitted to the coronary intensive care unit with a diagnosis of unstable angina pectoris. His medical history did not include any known heart disease. We performed transradial coronary angiography and identified severe occlusion in the proximal left anterior descending (LAD). Right coronary angiography revealed diffuse 70% occlusion after branching of acute marginal artery followed by 90% and 99% occlusion in the distal right coronary artery (RCA). The ostium of the posterior lateral artery (PLA) was totally occluded (Fig. 1a). We performed revascularization of the LAD first. Figure 1 (a) Pre-revascularization right coronary artery. (b) Right coronary artery post revascularization The ostium of RCA had an atypical take-off, and good cannulation was achieved via a 6F hockey stick guiding catheter. However, adequate back-up support could not be achieved to deliver PCI equipment to the distal vessel. We could not advance the floppy guidewire through the occlusions; therefore, a microcatheter assist device was used for wiring the distal RCA. We could not advance the percutaneous transluminal coronary angioplasty (PTCA) balloon through the most critical part of the occlusion. Therefore, we decided to use a guide extension catheter (Guidezilla 6F Boston Scientific) for effective cannulation and adequate back-up support. We advanced the PTCA balloons with the help of Guidezilla and predilated the lesions. After predilation, we could not advance the 2.0*28 mm DES; therefore, we retracted the stent and dilated the lesions with a 2.5 mm noncompliant balloon. When we tried to advance the 2.0*28 mm stent again, we could not advance it through the proximal junction of Guidezilla. We overcame this obstacle by dilating the proximal junction of the Guidezilla extension catheter with a 2.5*15 mm PTCA balloon with 14 atmospheric pressure (Fig. 2). After dilation, we advanced the stent with ease and deployed it in the distal RCA. Figure 2 Dilation of the proximal junction of Guidezilla Following deployment of the first stent, we deployed a 2.25*26 mm DES in 90% occlusion just before the crux and a 2.5*30 mm DES in the most proximal occlusion. After stent deployment, we post-dilated stents with noncompliant balloons (Fig. 1b). The patient was discharged two days later with marked improvement in his symptoms and no complications. Discussion In our case, the Guidezilla support extension catheter system helped us to cannulate the vessel better and allowed us to perform the operation successfully; however, we encountered a previously documented complication of Guidezilla - stent stripping due to difficulty in advancing the stent through the proximal junction of Guidezilla (6) - and developed a novel technique to prevent the occurrence of this adverse event. Stent stripping seems to be primarily associated with the Guidezilla support extension catheter system when compared with other guide extension catheters (such as the GuideLiner) due to the less elastic nature of the stainless steel collar of Guidezilla. The risk is particularly high with less flexible long stents (6). We have encountered this problem on numerous occasions and found that it is particularly difficult to advance a retracted stent into the proximal junction; similar to the occurrence in this particular case. While we know that manipulating the stent (such as rotating the stent or mild retraction of the guide extension catheter) (2) may help advance the stent, these maneuvers also increase the risk of stent stripping (5, 6). We believe that this problem arises from an interaction between the less flexible metal collar of Guidezilla and the metal composition of the stent. Alterations and deformations that arise while pushing the stent into the proximal junction of Guidezilla may be the plausible culprit as this complication is rare with balloons and more likely when a stent that was retracted earlier is implanted. The dilation of the proximal junction of Guidezilla does not increase the diameter of the junction significantly. Therefore, we do not think our maneuver functions by such a mechanism. We do think, however, that dilation of the junction causes structural alterations that allow a different alignment for the previously deformed stent. PTCA balloons of a diameter larger than the jammed stent could be easily advanced, supporting our belief that structural deformities caused by Guidezilla’s metal collar are the primary mechanism of this particular problem, rather than the insufficient diameter of the proximal junction. Another possible explanation could be the narrowing of the lumen due to a kinked guidewire. Depending on the structure of Guidezilla, a kinked wire might lead to an obstruction of the proximal junction in return. Balloon dilation of the proximal junction might have allowed stent advancement by flattening the guidewire, thus, relieving the obstruction. The risk of stent stripping is a rather common and distinct complication of Guidezilla among guide extension support catheters (6, 7) and our novel solution may provide a simple but efficient method to prevent this. Conclusion In conclusion, while advancing a stent into the Guidezilla guide extension catheter, our solution of dilating the proximal junction of Guidezilla might be a reasonable alternative to rotating the stent when resistance is encountered.

          Related collections

          Most cited references 7

          • Record: found
          • Abstract: found
          • Article: not found

          Guideliner catheter--friend or foe?

          Performing percutaneous coronary intervention (PCI) in arteries with complex anatomy remains a clinical problem. In particular tortuosity within a coronary vessel is frequently encountered and can hamper delivery of balloons or stents to coronary stenoses. This has led to the development of a number of adjuvant devices to assist stent delivery in difficult cases. The safety profile of these novel devices remains to be clearly ascertained. The Guideliner "child" support catheter is one such device and comprises of a 20-cm silicon-coated guide extension that assists delivery of stents in tortuous arteries when conventional techniques have failed. Initial reports suggest it is efficacious and no previous complications relating to the device have been published. We report the first complication involving the Guideliner catheter which was encountered during primary PCI. We hypothesize regarding the mechanism of the complication and discuss the ways it may be avoided in the future.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            The GuideLiner "child" catheter for percutaneous coronary intervention - early clinical experience.

            The failure to deliver a stent across the target lesion during percutaneous coronary intervention, especially in arteries with calcified tortuous anatomy, is often due to insufficient back-up support from the guiding catheter. Deep-vessel intubation with the guiding catheter may overcome this problem, but risks coronary dissection. The Heartrail II (Terumo, Japan) "five-in-six catheter system" (or "mother-and-child" catheter) comprises a flexible-tipped long 5 Fr catheter advanced through a standard 6 Fr guiding catheter to deeply intubate the target vessel, thus providing enough back-up support to enable stent delivery. Here we describe a newly developed "child" support catheter (The GuideLiner; Vascular Solutions, Inc., Minneapolis, Minnesota), report its successful use in a series of 4 difficult cases and discuss practical tips to optimize its performance.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              A unique complication of the GuideZilla guide extension support catheter and the risk of stent stripping in interventional & endovascular interventions

                Bookmark

                Author and article information

                Journal
                Anatol J Cardiol
                Anatol J Cardiol
                Anatolian Journal of Cardiology
                Kare Publishing (Turkey )
                2149-2263
                2149-2271
                September 2020
                : 24
                : 3
                : 203-205
                Affiliations
                Department of Cardiology, Faculty of Medicine, Ankara University; Ankara-Turkey
                Author notes
                Address for Correspondence: Dr. Kerim Esenboğa, Ankara Üniversitesi Tıp Fakültesi, Kardiyoloji Anabilim Dalı, Ankara- Türkiye Phone: +90 539 296 51 54 E-mail: kerimesenboga@ 123456yahoo.com
                Article
                AJC-24-203
                10.14744/AnatolJCardiol.2020.36900
                7585982
                32870167
                Copyright: © 2020 Turkish Society of Cardiology

                This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License

                Categories
                Case Reports

                Comments

                Comment on this article