      Ability of pulse power, esophageal Doppler, and arterial pulse pressure to estimate rapid changes in stroke volume in humans.

      Critical Care Medicine
      Aged, Blood Pressure, physiology, Echocardiography, Doppler, Echocardiography, Transesophageal, Humans, Male, Middle Aged, Monitoring, Physiologic, Pulse, Stroke Volume

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Measures of arterial pulse pressure variation and left ventricular stroke volume variation induced by positive-pressure breathing vary in proportion to preload responsiveness. However, the accuracy of commercially available devices to report dynamic left ventricular stroke volume variation has never been validated. We compared the accuracy of measured arterial pulse pressure and estimated left ventricular stroke volume reported from two Food and Drug Administration-approved aortic flow monitoring devices, one using arterial pulse power (LiDCOplus) and the other esophageal Doppler monitor (HemoSonic). We compared estimated left ventricular stroke volume and their changes during a venous occlusion and release maneuver to a calibrated aortic flow probe placed around the aortic root on a beat-to-beat basis in seven anesthetized open-chested cardiac surgery patients. Dynamic changes in arterial pulse pressure closely tracked left ventricular stroke volume changes (mean r .96). Both devices showed good agreement with steady-state apneic left ventricular stroke volume values and moderate agreement with dynamic changes in left ventricular stroke volume (esophageal Doppler monitor -1 +/- 22 mL, and pulse power -7 +/- 12 mL, bias +/- 2 sd). In general, the pulse power signals tended to underestimate left ventricular stroke volume at higher left ventricular stroke volume values. Arterial pulse pressure, as well as, left ventricular stroke volume estimated from esophageal Doppler monitor and pulse power reflects short-term steady-state left ventricular stroke volume values and tract dynamic changes in left ventricular stroke volume moderately well in humans.

          Related collections

          Author and article information

          Journal
          18824912
          2586847
          10.1097/CCM.0b013e31818b31f0

          Chemistry
          Aged,Blood Pressure,physiology,Echocardiography, Doppler,Echocardiography, Transesophageal,Humans,Male,Middle Aged,Monitoring, Physiologic,Pulse,Stroke Volume

          Comments

          Comment on this article