9
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Influence of the Hybrid Sewage Treatment Plant’s Exploitation on Its Operation Effectiveness in Rural Areas

      , ,
      Sustainability
      MDPI AG

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The article evaluates the effectiveness of the removal of organic pollutants—nitrogen and phosphorus—from household sewage in a hybrid bioreactor with a submerged fixed bed. The experiment was carried out in two exploitation variants that were both conducted in a laboratory model of the hybrid bioreactor: (I) cycles of 120 min of aeration and 60 min of no aeration with a constant sewage dosage, and (II) cycles 60 min of aeration and 60 min of no aeration, with a periodic sewage dosage in the no-aeration phase. The experiment was carried out on real sewage primarily treated in a septic tank. The amount of pollution removal was calculated and compared with the mandatory standards according to Polish law. Moreover, the susceptibility of the sewage to the biological treatment, nitrification, and denitrification activity was determined. The research shows a higher effectiveness for the 60/60 model in comparison to the 120/60 model. High operation efficiency was observed regarding the removal of organic pollution and nitrate nitrogen. The tested structure showed very low nitrification activity combined with intense denitrification. These processes were observed in the 60/60 variant. The structure was often overloaded with the nitrate nitrogen, which was considered to be the nitrification process inhibitor. It was suggested that phosphorus was also removed by the denitrifying bacteria.

          Related collections

          Most cited references48

          • Record: found
          • Abstract: not found
          • Article: not found

          A review on anaerobic–aerobic treatment of industrial and municipal wastewater

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Full scale performance of the aerobic granular sludge process for sewage treatment.

            Recently, aerobic granular sludge technology has been scaled-up and implemented for industrial and municipal wastewater treatment under the trade name Nereda(®). With full-scale references for industrial treatment application since 2006 and domestic sewage since 2009 only limited operating data have been presented in scientific literature so far. In this study performance, granulation and design considerations of an aerobic granular sludge plant on domestic wastewater at the WWTP Garmerwolde, the Netherlands were analysed. After a start-up period of approximately 5 months, a robust and stable granule bed (>8 g L(-1)) was formed and could be maintained thereafter, with a sludge volume index after 5 min settling of 45 mL g(-1). The granular sludge consisted for more than 80% of granules larger than 0.2 mm and more than 60% larger than 1 mm. Effluent requirements (7 mg N L(-1) and 1 mg P L(-1)) were easily met during summer and winter. Maximum volumetric conversion rates for nitrogen and phosphorus were respectively 0.17 and 0.24 kg (m(3) d)(-1). The energy usage was 13.9 kWh (PE150·year)(-1) which is 58-63 % lower than the average conventional activated sludge treatment plant in the Netherlands. Finally, this study demonstrated that aerobic granular sludge technology can effectively be implemented for the treatment of domestic wastewater.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Treated Wastewater Effluent as a Source of Microbial Pollution of Surface Water Resources

              Since 1990, more than 1.8 billion people have gained access to potable water and improved sanitation worldwide. Whilst this represents a vital step towards improving global health and well-being, accelerated population growth coupled with rapid urbanization has further strained existing water supplies. Whilst South Africa aims at spending 0.5% of its GDP on improving sanitation, additional factors such as hydrological variability and growing agricultural needs have further increased dependence on this finite resource. Increasing pressure on existing wastewater treatment plants has led to the discharge of inadequately treated effluent, reinforcing the need to improve and adopt more stringent methods for monitoring discharged effluent and surrounding water sources. This review provides an overview of the relative efficiencies of the different steps involved in wastewater treatment as well as the commonly detected microbial indicators with their associated health implications. In addition, it highlights the need to enforce more stringent measures to ensure compliance of treated effluent quality to the existing guidelines.
                Bookmark

                Author and article information

                Journal
                SUSTDE
                Sustainability
                Sustainability
                MDPI AG
                2071-1050
                August 2018
                August 01 2018
                : 10
                : 8
                : 2689
                Article
                10.3390/su10082689
                74515a32-1f3e-46f9-81eb-77760da186ed
                © 2018

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments