      An Innovative Needle-free Injection System: Comparison to 1 ml Standard Subcutaneous Injection.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A needle-free delivery system may lead to improved satisfaction and compliance, as well as reduced anxiety among patients requiring frequent or ongoing injections. This report describes a first-in-man assessment comparing Portal Instruments' innovative needle-free injection system with subcutaneous injections using a 27G needle. Forty healthy volunteer participants each received a total of four injections of 1.0 mL sterile saline solution, two with a standard subcutaneous injection using a 27G needle, and two using the Portal injection system. Perception of pain was measured using a 100-mm visual analog scale (VAS). Injection site reactions were assessed at 2 min and at 20-30 min after each injection. Follow-up contact was made 24-48 h after the injections. Subject preference regarding injection type was also assessed. VAS pain scores at Portal injection sites met the criteria to be considered non-inferior to the pain reported at 27G needle injection sites (i.e., upper 95% confidence bound less than +5 mm). Based on a mixed effects model, at time 0, accounting for potential confounding variables, the adjusted difference in VAS scores indicated that Portal injections were 6.5 mm lower than the 27G needle injections (95% CI -10.5, -2.5). No clinically important adverse events were noted. Portal injections were preferred by 24 (60%) of the subjects (P = 0.0015). As an early step in the development of this new needle-free delivery system, the current study has shown that a 1.0-mL saline injection can be given with less pain reported than a standard subcutaneous injection using a 27G needle.

          Related collections

          Author and article information

          Journal
          AAPS PharmSciTech
          AAPS PharmSciTech
          American Association of Pharmaceutical Scientists (AAPS)
          1530-9932
          1530-9932
          May 01 2017
          Affiliations
          [1 ] Portal Instruments, Inc., 190 Fifth Street, Cambridge, Massachusetts, 02141, USA. nikola.kojic@portalinstruments.com.
          [2 ] Portal Instruments, Inc., 190 Fifth Street, Cambridge, Massachusetts, 02141, USA.
          [3 ] Care-Safe Inc., Waltham, Massachusetts, USA.
          Article
          10.1208/s12249-017-0779-0
          10.1208/s12249-017-0779-0
          28462463
          75008464-e748-4ebb-aae6-99c299d40ee5
          History

          injection pain,injection site reactions,needle-free jet injections,subcutaneous injections

          Comments