19
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Analysis of flexible substrates for clinical translation of laser-generated shockwave therapy.

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Bacteria biofilms in chronically infected wounds significantly increase the burden of healthcare costs and resources for patients and clinics. Because biofilms are such an effective barrier to standard antibiotic treatment, new methods of therapy need to be developed to combat these infections. Our group has demonstrated the potential of using Laser Generated Shockwaves as a potential therapy to mechanically disrupt the bacterial biofilms covering the wound. Previous studies have used rigid silica glass as the shockwave propagation medium, which is not compatible with the intended clinical application. This paper describes the exploration of five candidate flexible plastic films to replace the glass substrate. Each material measured 0.254 mm thick and was used to generate shockwaves of varying intensities. Shockwave characterization was performed using a high-speed Michelson displacement interferometer and peak stress values obtained in the flexible substrates were compared to glass using one-way nested Analysis of Variance and Tukey HSD post-hoc analysis. Results demonstrate statistically significant differences between substrate material and indicate that polycarbonate achieves the highest peak stress for a given laser fluence suggesting that it is optimal for clinical applications.

          Related collections

          Author and article information

          Journal
          Biomed Opt Express
          Biomedical optics express
          2156-7085
          Mar 1 2015
          : 6
          : 3
          Affiliations
          [1 ] Department of Bioengineering, University of California Los Angeles, 420 Westwood Plaza, Los Angeles, CA 90024, USA.
          [2 ] Department of Bioengineering, University of California Los Angeles, 420 Westwood Plaza, Los Angeles, CA 90024, USA ; Department of Electrical Engineering, University of California Los Angeles, 420 Westwood Plaza, Los Angeles, CA 90024, USA ; Department of Surgery, University of California Los Angeles, 420 Westwood Plaza, Los Angeles, CA 90024, USA.
          Article
          220313
          10.1364/BOE.6.000827
          4361437
          25798307
          759a33c2-2af3-424d-affc-1fba256703a9
          History

          (120.0120) Instrumentation, measurement, and metrology,(120.3890) Medical optics instrumentation

          Comments

          Comment on this article