      High-volume postdilution hemodiafiltration is a feasible option in routine clinical practice

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Hemodiafiltration (HDF) with 20–22 L of substitution fluid is increasingly recognized as associated with significant benefits regarding patient outcome. However, some doubt exists as to whether these high volumes can be achieved in routine clinical practice. A total of 4176 sessions with 366 patients on postdilution HDF were analyzed in this 1-month observational cohort study with prospective data collection. All dialysis machines were equipped with AutoSub plus signal analysis software that automatically and continuously adapts the substitution fluid flow according to the blood flow, blood viscosity, and dialyzer characteristics. Percentages of sessions with different types of vascular access were compared regarding achievement of ≥21 L substitution fluid. Logistic regression analysis was conducted to study the independent relationship of selected variables with achievement of ≥21 L substitution volume. Patient- and dialysis-related variables that showed an association with the convection volume were entered in a multivariable model that included hematocrit up front. Respectively, 87%, 84%, and 33% of routine sessions conducted with fistulas, grafts, and catheters qualified as high-volume HDF. Serum albumin levels ≥4.2 g/dL were positively associated with the achievement of at least 21 L substitution volume. Positive associations were also observed for blood flows in the ranges 350–399 and ≥400 mL/min compared with the reference range (300–350 mL/min), for longer treatment time, for fistula versus catheter, for higher filtration fraction, and for dialysis conducted at the end of the week versus Monday. It can be concluded that implementation and sustainability of high-volume HDF is possible in routine clinical practice for almost all patients treated with fistulas and grafts.

          Related collections

          Most cited references15

          • Record: found
          • Abstract: found
          • Article: not found

          Fluid retention is associated with cardiovascular mortality in patients undergoing long-term hemodialysis.

          Patients with chronic kidney disease (stage 5) who undergo hemodialysis treatment have similarities to heart failure patients in that both populations retain fluid frequently and have excessively high mortality. Volume overload in heart failure is associated with worse outcomes. We hypothesized that in hemodialysis patients, greater interdialytic fluid gain is associated with poor all-cause and cardiovascular survival. We examined 2-year (July 2001 to June 2003) mortality in 34,107 hemodialysis patients across the United States who had an average weight gain of at least 0.5 kg above their end-dialysis dry weight by the time the subsequent hemodialysis treatment started. The 3-month averaged interdialytic weight gain was divided into 8 categories of 0.5-kg increments (up to > or =4.0 kg). Eighty-six percent of patients gained >1.5 kg between 2 dialysis sessions. In unadjusted analyses, higher weight gain was associated with better nutritional status (higher protein intake, serum albumin, and body mass index) and tended to be linked to greater survival. However, after multivariate adjustment for demographics (case mix) and surrogates of malnutrition-inflammation complex, higher weight-gain increments were associated with increased risk of all-cause and cardiovascular death. The hazard ratios (95% confidence intervals) of cardiovascular death for weight gain or =4.0 kg (compared with 1.5 to 2.0 kg as the reference) were 0.67 (0.58 to 0.76) and 1.25 (1.12 to 1.39), respectively. In hemodialysis patients, greater fluid retention between 2 subsequent hemodialysis treatment sessions is associated with higher risk of all-cause and cardiovascular death. The mechanisms by which fluid retention influences cardiovascular survival in hemodialysis may be similar to those in patients with heart failure and warrant further research.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Longer treatment time and slower ultrafiltration in hemodialysis: associations with reduced mortality in the DOPPS.

            Longer treatment time (TT) and slower ultrafiltration rate (UFR) are considered advantageous for hemodialysis (HD) patients. The study included 22,000 HD patients from seven countries in the Dialysis Outcomes and Practice Patterns Study (DOPPS). Logistic regression was used to study predictors of TT > 240 min and UFR > 10 ml/h/kg bodyweight. Cox regression was used for survival analyses. Statistical adjustments were made for patient demographics, comorbidities, dose of dialysis (Kt/V), and body size. Europe and Japan had significantly longer (P 240 min was independently associated with significantly lower relative risk (RR) of mortality (RR = 0.81; P = 0.0005). Every 30 min longer on HD was associated with a 7% lower RR of mortality (RR = 0.93; P 10 ml/h/kg was associated with higher odds of intradialytic hypotension (odds ratio = 1.30; P = 0.045) and a higher risk of mortality (RR = 1.09; P = 0.02). Longer TT and higher Kt/V were independently as well as synergistically associated with lower mortality. Rapid UFR during HD was also associated with higher mortality risk. These results warrant a randomized clinical trial of longer dialysis sessions in thrice-weekly HD.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Patient- and treatment-related determinants of convective volume in post-dilution haemodiafiltration in clinical practice.

              Large convective volumes are recommended for online haemodiafiltration (HDF) to maximize solute removal. There has been little systematic evaluation of factors that determine convective volumes in routine clinical practice.
                Bookmark

                Author and article information

                Journal
                Artif Organs
                Artif Organs
                aor
                Artificial Organs
                BlackWell Publishing Ltd (Oxford, UK )
                0160-564X
                1525-1594
                February 2015
                02 October 2014
                : 39
                : 2
                : 142-149
                Affiliations
                [* ]Fresenius Medical Care Bad Homburg, Germany
                []NephroCare Lumiar Lisbon, Portugal
                []NephroCare Guarda Guarda, Portugal
                [§ ]Fresenius Medical Care Schweinfurt, Germany
                Author notes
                Address correspondence and reprint requests to Prof. Daniele Marcelli, EMEALA Medical Board, Fresenius Medical Care, Else-Kroener-Strasse 1, Bad Homburg 61352, Germany. E-mail: daniele.marcelli@ 123456fmc-ag.de
                Article
                10.1111/aor.12345
                4354295
                25277688
                76c77b6f-22b7-4548-b7d2-e0c731e3bf59
                © 2014 The Authors. Artificial Organs published by Wiley Periodicals, Inc. on behalf of International Center for Artificial Organ and Transplantation (ICAOT).

                This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.

                History
                : February 2014
                : April 2014
                Categories
                Main Text Articles

                Transplantation
                hemodiafiltration,high-volume,substitution fluid,dialysis
                Transplantation
                hemodiafiltration, high-volume, substitution fluid, dialysis

                Comments

                Comment on this article