      Improved data acquisition efficiency for respiratory motion correction in coronary MRI

      abstract

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Summary To investigate the performance of a novel algorithm for correcting respiratory-induced heart motion for whole-heart coronary MRI. Background A right hemi-diaphragm (RHD) respiratory navigator is commonly used to suppress the respiratory motion of the heart in coronary MRI [1]. Typically, a small 5mm end expiratory gating window (GW) is used to gate data. While this technique successfully suppresses respiratory motion, it prolongs scan time due to navigator efficacies of only 30-50%. Increasing the GW to 15mm would increase the navigator efficiency. In this study, we present a novel respiratory motion correction algorithm which allows increasing the GW to 15mm. Methods Whole-heart coronary MRI with isotropic 1.3mm3 resolution was acquired using partial Fourier and a navigator with 15mm GW on a 1.5T Philips CMR scanner from 10 healthy subjects (4 males; 29 ± 13 yr). The navigator RHD positions were used to sort the acquired k-space segments into 15 separate 1mm bins (based on their displacement). To compensate for the respiratory motion of the heart, all k-space segments acquired in each bin were assigned a 3D translation parameter. The 3D translation parameter was estimated using an iterative gradient descent optimization algorithm to correct the k-space segments such that the sharpness of the image, reconstructed using the corrected k-space segments, is maximized. The variance of the gradient of the image was used as the measure for the image sharpness [2]. For comparison, another whole-heart coronary MRI dataset was acquired using the same sequence and a navigator with a 5mm GW. Results Fig.1 displays multi-planner reformatted images acquired using a 5mm GW (A), a 15mm GW without correction (B) and a 15mm GW with the proposed correction technique (C). There is an improvement between images acquired using 15mm GW with correction. The mean and standard deviation of scan acquisition time and efficiency as well as mean and standard deviation of normalized vessel sharpness of right coronary artery (RCA), left anterior descending (LAD) and left circumflex (LCX) arteries are shown in Table 1. However there is an improvement in the mean of the sharpness of LAD and LCX using the proposed technique compared to the reference, but it is not significantly different. Figure 1 Reformatted whole-heart coronary MRI acquired from three healthy subjects using A) a right hemi-diaphragm (RHD) navigator with a 5 mm gating window; B) a RHD navigator with 15 mm gating window without correction and C) a RHD navigator with 15 mm gating window with correction. Arrows identify the left anterior descending (LAD) and left circumflex (LCX) arteries. Table 1 Quantitative comparison between the whole-heart coronary MRI acquired with a navigator with a 5 mm gating window (GW), 15 mm GW without correction (noMC), and 15 mm GW with correction (MC) using the proposed algorithm. Higher values of sharpness are superior. All values are reported as mean ± standard deviation, and all statistically significant p values are in bold. Parameter 5mm GW (REF) 15mm GW without Correction (noMC) 15mm GW with Correction (MC) p value (n=10) MC vs. REF noMC vs. REF MC vs. noMC Imaging time (min.) 14 ± 5 7 ± 1 7 ± 1 <0.002 <0.002 - Scan efficiency (%) 55 ± 13 92 ± 8 92 ± 8 <0.001 <0.001 - RCA sharpness (mm-1) 0.51 ± 0.10 0.42 ± 0.17 0.49 ± 0.13 0.692 0.151 0.298 LAD sharpness (mm-1) 0.37 ± 0.15 0.29 ± 0.16 0.39 ± 0.04 0.683 0.271 0.079 LCX sharpness (mm-1) 0.33 ± 0.25 0.21± 0.19 0.38 ± 0.15 0.574 0.271 <0.047 Conclusions We present a novel retrospective RHD motion compensation algorithm for whole-heart coronary MRI that allows for widening GW and reduces scan acquisition time by a factor of 2. Funding NIH.

          Related collections

          Author and article information

          Conference
          J Cardiovasc Magn Reson
          Journal of Cardiovascular Magnetic Resonance
          BioMed Central
          1097-6647
          1532-429X
          2012
          1 February 2012
          : 14
          : Suppl 1
          : P246
          Affiliations
          [1 ]Harvard Medical School, Cambridge, MA, USA
          [2 ]Medicine, Beth Isreal Deaconess Medical Center, Boston, MA, USA
          Article
          1532-429X-14-S1-P246
          10.1186/1532-429X-14-S1-P246
          3304968
          76d0d2e4-79c9-453d-b47c-96b481e0e352
          Copyright ©2012 Moghari et al; licensee BioMed Central Ltd.

          This is an open access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

          15th Annual SCMR Scientific Sessions
          Orlando, FL, USA
          2-5 February 2012
          History
          Categories
          Poster Presentation

          Cardiovascular Medicine
          Cardiovascular Medicine

          Comments

          Comment on this article