      Comparative study of 27-gauge vs 25-gauge vitrectomy for epiretinal membrane

      other

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          The purpose of this study was to compare 27-gauge (27G) with 25-gauge (25G) microincision vitrectomy in patients with epiretinal membrane (ERM).

          Participants

          Seventy-four eyes of 66 patients undergoing 3-port pars plana vitrectomy using 27G or 25G instrumentation.

          Methods

          Seventy-four eyes of 66 patients with ERM, who underwent 27G or 25G microincision vitrectomy were prospectively evaluated.

          Results

          The mean operation time for vitrectomy was significantly longer in the 27G group than in the 25G group (9.9±3.5 vs 6.2±2.7 min, respectively, P<0.0001). No statistically significant difference was found between the two groups in terms of the mean operation time for ERM–inner limiting membrane peeling (27G vs 25G: 20.2±9.9 vs 16.1±9.3 min, P=0.14), although the time for vitreous cutting was longer in the 27G group (9.9±3.5 vs 6.2±2.7 min, respectively, P<0.0001). The flare value, intraocular pressure (IOP), and rate of hypotony 1 day after surgery did not differ between the 27G and 25G groups (flare value: 18.7 vs 17.2; IOP: 8.8 vs 9.7 mm Hg; rate of hypotony: 30 vs 35%, respectively). There was no significant difference in the surgically induced astigmatism between the two groups in the follow-up period. The mean time required for wound closure did not show a significant difference between the 27G and 25G groups (7.7 vs 8.6 weeks, respectively).

          Conclusion

          The 27G system is as safe and useful for ERM vitrectomy as the 25G system. Based on its potential, further improvement of 27G instruments could result in greater efficiency.

          Related collections

          Most cited references21

          • Record: found
          • Abstract: found
          • Article: not found

          A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery.

          To introduce and evaluate the infusion and aspiration rates and operative times of the 25-gauge transconjunctival sutureless vitrectomy system (TSV) DESIGN: In vitro experimental and comparative interventional study. Twenty eyes of 20 patients underwent a variety of vitreoretinal procedures using the 25-gauge TSV, including idiopathic epiretinal membrane (n = 10), macular hole (n = 4), rhegmatogenous retinal detachment (n = 3), branch retinal vein occlusion (n = 2), diabetic vitreous hemorrhage (n = 1), and 20 cases similar in diagnosis and severity were matched to provide comparison between duration of individual portions of the surgical procedures with the existing 20-gauge vitrectomy system. Description of the 25-gauge TSV is provided; infusion and aspiration rates of the 25-gauge and standard 20-gauge vitrectomy system were measured in vitro using balanced saline solution and porcine vitreous for several levels of aspirating power and bottle height, and operating times of individual portions of surgical procedures were measured for the 25-gauge and 20-gauge vitrectomy system. Infusion, aspiration rates, and operative times of the 20-gauge and 25-gauge vitrectomy system. Infusion and aspiration rates of the 25-gauge TSV system were reduced by an average of 6.9 and 6.6 times, respectively, compared with the 20-gauge system when balanced saline solution was used. The average flow rate of the Storz 25-gauge cutter (at 500 mmHg, 1500 cuts per minute [cpm]) was 40% greater than that of the 20-gauge pneumatic cutter (at 250 mmHg, 750 cpm) but about 2.3 times less than the 20-gauge high-speed cutter (at 250 mmHg, 1500 cpm). Mean total operative time was significantly greater for the 20-gauge high-speed cutter (26 minutes, 7 seconds) than for the 25-gauge vitrectomy system (17 minutes, 17 seconds) (P = 0.011). Although the infusion and aspiration rates of the 25-gauge instruments are lower than those for the 20-gauge high-speed vitrectomy system, the use of 25-gauge TVS may effectively reduce operative times of select cases that do not require the full capability of conventional vitrectomy.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            A 27-gauge instrument system for transconjunctival sutureless microincision vitrectomy surgery.

            To evaluate the efficiency, preliminary safety, and feasibility of a 27-gauge instrument system for transconjunctival microincision vitrectomy surgery (MIVS) in a variety of vitreoretinal diseases.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Transconjunctival sutureless 23-gauge vitrectomy.

                Bookmark

                Author and article information

                Journal
                Eye (Lond)
                Eye (Lond)
                Eye
                Nature Publishing Group
                0950-222X
                1476-5454
                April 2016
                08 January 2016
                1 April 2016
                : 30
                : 4
                : 538-544
                Affiliations
                [1 ]Department of Ophthalmology, St Marianna University School of Medicine , Kawasaki, Kanagawa, Japan
                Author notes
                [* ]Department of Ophthalmology, St Marianna University School of Medicine , 2-16-1 Sugao, Miyamae-ku, Kawasaki, Kanagawa 215-8511, Japan Tel: 81 44 977 8111; Fax: +81 44 976 7435. E-mail: kogo@ 123456marianna-u.ac.jp
                Article
                eye2015275
                10.1038/eye.2015.275
                5108536
                26742862
                785774ed-bc36-43ff-a9a7-b899e9ca287e
                Copyright © 2016 Royal College of Ophthalmologists

                This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License. The images or other third party material in this article are included in the article's Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/4.0/

                History
                : 18 August 2015
                : 10 November 2015
                Categories
                Clinical Study

                Vision sciences
                Vision sciences

                Comments

                Comment on this article