          Abstract

          The coronary sinus (CS) has become a clinically important structure especially through its role in providing access for different cardiac procedures such as arrhythmia ablation, biventricular pacing and recently, percutaneous valvular interventions. Fluoroscopy with or without two-dimensional transesophageal echocardiography is the widely used method for guidance. A 78-year-old female patient undergoing percutaneous CARILLON mitral annuloplasty device therapy for chronic severe symptomatic mitral regurgitation. After insertion of the CS catheter through the right internal jugular vein, multiple trials for CS cannulation guided by fluoroscopy and two-dimensional transesophageal echocardiography were unsuccessful. So, real time three-dimensional zoom mode was used. Then, the volume was rotated to have the anatomically oriented enface view of the interatrial septum from the right atrial perspective. The CS ostium was identified adjacent to the eustachian valve. Then the catheter was reintroduced through the superior vena cava into the right atrium then easily navigated to cannulate the CS ostium. The position was confirmed by the fluoroscopically known course of the CS plus the pattern of the invasive pressure wave form. CS cannulation is not always feasible using fluoroscopy and/or two-dimensional Echocardiography guidance. Real time three-dimensional transesophageal echocardiography can be used to guide CS cannulation as it provides an anatomically oriented and informative enface view of the CS ostium. It can help reducing fluoroscopic radiation time.

          Related collections

          Author and article information

          Journal
          Echocardiography
          Echocardiography (Mount Kisco, N.Y.)
          1540-8175
          0742-2822
          Jan 2015
          : 32
          : 1
          Affiliations
          [1 ] Adult Cardiology Department, Prince Sultan Cardiac Center, Al-Ahsa, Hofuf, Saudi Arabia.
          Article
          10.1111/echo.12745
          25231878
          7946a5c0-d3f8-4fa5-8daa-2d35b136a6b5
          © 2014, Wiley Periodicals, Inc.
          History

          3D-TEE,coronary sinus,mitral insufficiency
          3D-TEE, coronary sinus, mitral insufficiency

          Comments

          Comment on this article