8
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Recent Developments of Intraoperative Neuromonitoring in Thyroidectomy

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          At present, intraoperative neuromonitorization (IONM) with surface electrode-based endotracheal tube (ETT) is a standard method in thyroidectomy and can be performed either intermittently IONM (I-IONM) or continuously IONM (C-IONM). Despite the valuable contribution of I-IONM to the thyroidectomy, it still has limitations regarding the recording electrodes and stimulation probe. New approaches for overcoming the limitations of I-IONM and developing the method are taking attention. Most of the technical issues of IONM with surface electrode-based ETT are related with inadequate contact of electrodes to the vocal cords. Nowadays, efficiency of various recording electrodes is under investigation. Recording electrodes such as needle electrodes applied to thyroarytenoid or posterior cricoarytenoid muscle (PCA), surface electrodes applied to the PCA, and needle or adhesive electrodes applied to the tracheal cartilage or skin, can make safe recordings similar to the ETT electrodes. Despite their invasiveness, needle electrodes record higher electromyography (EMG) amplitudes than tube electrodes do. Adhesive surface electrodes make safe EMG recordings, although amplitudes of these electrodes are usually lower than those of the tube electrodes. These different types of electrodes are less affected by tracheal manipulations and amplitude changes are lower compared to the tube electrodes.

          During C-IONM, an additional stimulation probe is applied to the vagus nerve after dissecting the nerve circumferentially. Recently, without applying a probe, a new continuous monitorization method called laryngeal adductor reflex CIONM (LAR-CIONM) using sensorial, central, and motor components of LAR arch which is an automatic, primitive brainstem reflex protecting the tracheoesophageal tree from foreign body aspiration, has been implemented. Afferent track of LAR communicates laryngeal mucosa to the brainstem by internal branch of the superior laryngeal nerve and efferent track reaches larynx through recurrent laryngeal nerve. Total outcome of LAR activation is the closure of laryngeal entry by bilateral vocal cord adduction. In LAR-CIONM, a stimulus is given by an electrode from one side of surface electrode-based ETT and amplitude response of the LAR at the vocal cord is followed on the operation side. Recently, it has been reported that real-time EMG response can be obtained with stimulation probe cables applied to dissectors or energy devices during the dissection through I-IONM.

          Related collections

          Most cited references46

          • Record: found
          • Abstract: found
          • Article: not found

          Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement.

          Intraoperative neural monitoring (IONM) during thyroid and parathyroid surgery has gained widespread acceptance as an adjunct to the gold standard of visual nerve identification. Despite the increasing use of IONM, review of the literature and clinical experience confirms there is little uniformity in application of and results from nerve monitoring across different centers. We provide a review of the literature and cumulative experience of the multidisciplinary International Neural Monitoring Study Group with IONM spanning nearly 15 years. The study group focused its initial work on formulation of standards in IONM as it relates to important areas: 1) standards of equipment setup/endotracheal tube placement and 2) standards of loss of signal evaluation/intraoperative problem-solving algorithm. The use of standardized methods and reporting will provide greater uniformity in application of IONM. In addition, this report clarifies the limitations of IONM and helps identify areas where additional research is necessary. This guideline is, at its forefront, quality driven; it is intended to improve the quality of neural monitoring, to translate the best available evidence into clinical practice to promote best practices. We hope this work will minimize inappropriate variations in monitoring rather than to dictate practice options.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Intraoperative neuromonitoring for the early detection and prevention of RLN traction injury in thyroid surgery: a porcine model.

            Operative traction of the thyroid lobe is a necessary component of thyroid surgery. This surgical maneuver can cause traction injury of the recurrent laryngeal nerve (RLN), and this complication has been reported to be the most common mechanism of nerve injury. The goal of this study was to investigate the electromyographic (EMG) signal pattern during an acute RLN traction injury and establish reliable strategies to prevent the injury using intraoperative neuromonitoring (IONM).
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found
              Is Open Access

              Comparison of EMG signals recorded by surface electrodes on endotracheal tube and thyroid cartilage during monitored thyroidectomy

              A variety of electromyography (EMG) recording methods were reported during intraoperative neural monitoring (IONM) of recurrent laryngeal nerve (RLN) in thyroid surgery. This study compared two surface recording methods that were obtained by electrodes on endotracheal tube (ET) and thyroid cartilage (TC). This study analyzed 205 RLNs at risk in 110 patients undergoing monitored thyroidectomy. Each patient was intubated with an EMG ET during general anesthesia. A pair of single needle electrode was inserted obliquely into the TC lamina on each side. Standard IONM procedure was routinely followed, and EMG signals recorded by the ET and TC electrodes at each step were compared. In all nerves, evoked laryngeal EMG signals were reliably recorded by the ET and TC electrodes, and showed the same typical waveform and latency. The EMG signals recorded by the TC electrodes showed significantly higher amplitudes and stability compared to those by the ET electrodes. Both recording methods accurately detected 7 partial loss of signal (LOS) and 2 complete LOS events caused by traction stress, but only the ET electrodes falsely detected 3 LOS events caused by ET displacement during surgical manipulation. Two patients with true complete LOS experienced temporary RLN palsy postoperatively. Neither permanent RLN palsy, nor complications from ET or TC electrodes were encountered in this study. Both electrodes are effective and reliable for recording laryngeal EMG signals during monitored thyroidectomy. Compared to ET electrodes, TC electrodes obtain higher and more stable EMG signals as well as fewer false EMG results during IONM.
                Bookmark

                Author and article information

                Journal
                Sisli Etfal Hastan Tip Bul
                Sisli Etfal Hastan Tip Bul
                The Medical Bulletin of Sisli Etfal Hospital
                Kare Publishing (Turkey )
                1302-7123
                1308-5123
                2021
                24 September 2021
                : 55
                : 3
                : 273-285
                Affiliations
                [1 ]Department of General Surgery, University of Health Sciences Turkey, Sisli Hamidiye Etfal Training and Research Hospital, Istanbul, Turkey
                [2 ]Department of General Surgery, Bahcesehir University Faculty of Medicine, Istanbul; Sisli Memorial Hospital, Istanbul, Turkey
                Author notes
                Address for correspondence: Mehmet Kostek, MD. Etfal Sk. Sisli Hamidiye Etfal Egitim ve Arastirma Hastanesi, 4. Kat C Blok Genel Cerrahi Klinigi, Sisli, Istanbul/Turkey Phone: +90 212 373 50 00 E-mail: dr.mkostek@ 123456gmail.com
                Article
                MBSEH-55-273
                10.14744/SEMB.2021.26675
                8526228
                34712067
                79f31ecc-ebc6-4522-b09f-b500d111ab3e
                Copyright: © 2021 by The Medical Bulletin of Sisli Etfal Hospital

                This is an open access article under the CC BY-NC license ( http://creativecommons.org/licenses/by-nc/4.0/).

                History
                : 10 August 2021
                : 16 August 2021
                Categories
                Review

                electromyography,neuromonitorization,recurrent laryngeal nerve,superior laryngeal nerve