16
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Analysis of anthelmintics in surface water by ultra high performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A method based on ultra high performance liquid chromatography coupled to quadrupole linear ion trap mass spectrometry (UHPLC-QqLIT-MS) has been developed to investigate occurrence of 10 anthelmintic drugs from different structural groups (moxidectin, flubendazole, fenbendazole, levamisol, mebendazole, oxibendazole, albendazole, triclabendazole, febantel and praziquantel) in surface water. Analytes were pre-concentrated by solid phase extraction (SPE) using hydrophilic-lipophilic polymeric based sorbent. Quantification of investigated analytes was done using deuterated compounds as internal standards in order to minimize matrix effect. Analyte recoveries from spiked samples at two concentration levels were above 75% for most of the analytes. The main advantages of developed method are fast separation using UHPLC and therefore short analysis time, combined with good sensitivity which is demonstrated by low ngL(-1) detection limits. The developed method was applied for analysis of anthelmintics in the Llobregat River (NE Spain) and its main tributaries (rivers Anoia and Cardener). Eight out of ten anthelmintics were detected in all analyzed samples with the concentrations in low ngL(-1) level. The method fills the gap on analytical methodologies for determination of anthelmintic drugs in the environment.

          Related collections

          Author and article information

          Journal
          Chemosphere
          Chemosphere
          Elsevier BV
          1879-1298
          0045-6535
          Mar 2014
          : 99
          Affiliations
          [1 ] Department of Analytical Chemistry, Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev trg 19, Zagreb, Croatia; Catalan Institute for Water Research (ICRA), Girona, Spain. Electronic address: mzrncic@fkit.hr.
          [2 ] Catalan Institute for Water Research (ICRA), Girona, Spain.
          [3 ] Department of Analytical Chemistry, Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev trg 19, Zagreb, Croatia.
          [4 ] Catalan Institute for Water Research (ICRA), Girona, Spain; Department of Environmental Chemistry, IDAEA-CSIC, Barcelona, Spain.
          [5 ] Catalan Institute for Water Research (ICRA), Girona, Spain; Catalan Institution for Research and Advanced Studies (ICREA), Barcelona, Spain.
          Article
          S0045-6535(13)01572-5
          10.1016/j.chemosphere.2013.10.091
          24289978
          7ce919ab-9d81-41a5-9bb6-134b321961f1
          History

          Anthelmintics,Ultra high performance liquid chromatography,Pharmaceuticals,Quadrupole linear ion trap,Solid phase extraction,Surface water

          Comments

          Comment on this article